Low-Power, +3V/+5V, 400MHz Single-Supply
Op Amps with Rail-to-Rail Outputs
AC ELECTRICAL CHARACTERISTICS (continued)
(VCC = +5V, VEE = 0, VCM = +1.75V, RL = 1kΩ connected to VCC/2, CL = 5pF, AVCL = +1V/V, TA = +25°C, unless otherwise noted.)
PARAMETER
Slew Rate
Rise/Fall Time
Settling Time
Spurious-Free Dynamic Range
SYMBOL
CONDITIONS
MAX4414/MAX4416/
MAX4418, AV = +1V/V
SR
VOUT = 2V step
MAX4415/MAX4417/
MAX4419, AV = +5V/V
tR, tF
VOUT = 2V step,
10% to 90%
MAX4414/MAX4416/
MAX4418, AV = +1V/V
MAX4415/MAX4417/
MAX4419, AV = +5V/V
tS 1%
VOUT = 2V step
MAX4414/MAX4416/
MAX4418, AV = +1V/V
MAX4415/MAX4417/
MAX4419, AV = +5V/V
tS 0.1% VOUT = 2V step
MAX4414/MAX4416/
MAX4418, AV = +1V/V
MAX4415/MAX4417/
MAX4419, AV = +5V/V
VCC = +5V,
fC = 5MHz
SFDR
VCC = +3V,
fC = 5MHz
MAX4414/MAX4416/
MAX4418, AV = +1V/V,
VOUT = 1Vp-p
MAX4415/MAX4417/
MAX4419, AV = +5V/V,
VOUT = 2Vp-p
MAX4414/MAX4416/
MAX4418, AV = +1V/V,
VOUT = 1Vp-p
MAX4415/MAX4417/
MAX4419, AV = +5V/V,
VOUT = 2Vp-p
MIN TYP MAX UNITS
200
V/µs
470
14
ns
5
100
120
ns
150
160
-84
-76
dBc
-93
-79
4 _______________________________________________________________________________________