DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MC-4564EC727 查看數據表(PDF) - NEC => Renesas Technology

零件编号
产品描述 (功能)
生产厂家
MC-4564EC727 Datasheet PDF : 16 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
MC-4564EC727
DC Characteristics (Recommended Operating Conditions unless otherwise noted)
Parameter
Symbol
Test condition
Grade MIN. MAX. Unit Notes
5 Operating current
ICC1 Burst length = 1
5
tRC tRC (MIN.), IO = 0 mA
5
Precharge standby current in ICC2P CKE VIL (MAX.), tCK = 15 ns
/CAS latency = 2 -A75
/CAS latency = 3 -A75
2,740 mA 1
2,830
286 mA
5 power down mode
ICC2PS CKE VIL (MAX.), tCK =
116
5 Precharge standby current in ICC2N CKE VIH (MIN.), tCK = 15 ns, /CS VIH (MIN.),
5 non power down mode
Input signals are changed one time during 30 ns.
970 mA
5
ICC2NS CKE VIH (MIN.), tCK = , Input signals are stable.
368
5 Active standby current in
ICC3P CKE VIL (MAX.), tCK = 15 ns
430 mA
5 power down mode
5 Active standby current in
5 non power down mode
ICC3PS CKE VIL (MAX.), tCK =
ICC3N CKE VIH (MIN.), tCK = 15 ns, /CS VIH (MIN.),
Input signals are changed one time during 30 ns.
224
1,330 mA
5
ICC3NS CKE VIH (MIN.), tCK = , Input signals are stable.
5 Operating current
ICC4 tCK tCK (MIN.), IO = 0 mA
/CAS latency = 2 -A75
5 (Burst mode)
/CAS latency = 3 -A75
5 CBR (Auto) Refresh current
ICC5
tRC tRC (MIN.)
/CAS latency = 2 -A75
5
/CAS latency = 3 -A75
5 Self refresh current
ICC6 CKE 0.2 V
970
2,830 mA 2
3,460
5,080 mA 3
5,260
322 mA
Input leakage current
II (L) VI = 0 to 3.6 V, All other pins not under test = 0 V
–20 +20 µA
Input leakage current (CKE0)
–40 +40
Input leakage current
(/CS0-/CS3, DQMB0-DQMB7)
–10 +10
Output leakage current
IO (L) DOUT is disabled, VO = 0 to 3.6 V
–3 +3 µA
High level output voltage
VOH IO = –4.0 mA
2.4
V
Low level output voltage
VOL IO = +4.0 mA
0.4 V
Notes 1. ICC1 depends on output loading and cycle rates. Specified values are obtained with the output open.
In addition to this, ICC1 is measured on condition that addresses are changed only one time during tCK (MIN.).
2. ICC4 depends on output loading and cycle rates. Specified values are obtained with the output open.
In addition to this, ICC4 is measured on condition that addresses are changed only one time during tCK (MIN.).
3. ICC5 is measured on condition that addresses are changed only one time during tCK (MIN.).
Data Sheet M14461EJ2V0DS00
7

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]