DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MC-4532CC726XFA-A80 查看數據表(PDF) - Elpida Memory, Inc

零件编号
产品描述 (功能)
生产厂家
MC-4532CC726XFA-A80 Datasheet PDF : 14 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
MC-4532CC726XFA
DC Characteristics (Recommended Operating Conditions Unless Otherwise Noted)
Parameter
Symbol
Test condition
MIN. MAX. Unit Notes
Operating current
ICC1 Burst length = 1
tRC tRC(MIN.), IO = 0 mA
/CAS latency = 2
/CAS latency = 3
1,170 mA 1
1,170
Precharge standby current in ICC2P CKE VIL(MAX.), tCK = 15 ns
18 mA
power down mode
ICC2PS CKE VIL(MAX.), tCK =
Precharge standby current in ICC2N CKE VIH(MIN.), tCK = 15 ns, /CS VIH(MIN.),
non power down mode
Input signals are changed one time during 30 ns.
ICC2NS CKE VIH(MIN.), tCK =
Input signals are stable.
EActive standby current in
ICC3P CKE VIL(MAX.), tCK = 15 ns
power down mode
ICC3PS CKE VIL(MAX.), tCK =
Active standby current in
ICC3N CKE VIH(MIN.), tCK = 15 ns, /CS VIH(MIN.),
Onon power down mode
Input signals are changed one time during 30 ns.
ICC3NS CKE VIH(MIN.), tCK = , Input signals are stable.
Operating current
ICC4 tCK tCK(MIN.)
/CAS latency = 2
L (Burst mode)
IO = 0 mA
/CAS latency = 3
18
360 mA
108
90 mA
72
450 mA
360
1,350 mA 2
1,575
CBR (Auto) refresh current
ICC5 tRC tRC(MIN.)
/CAS latency = 2
2,340 mA 3
/CAS latency = 3
2,340
Self refresh current
ICC6 CKE 0.2 V
36 mA
Input leakage current
II(L) VI = 0 to 3.6 V, All other pins not under test = 0 V
– 18 + 18 µA
Input leakage current (CKE1)
–500 +500 µA
P Output leakage current
IO(L) DOUT is disabled, VO = 0 to 3.6 V
– 3 + 3 µA
High level output voltage
VOH IO = – 4.0 mA
2.4
V
Low level output voltage
VOL IO = + 4.0 mA
0.4 V
r Notes 1. ICC1 depends on output loading and cycle rates. Specified values are obtained with the output open. In
addition to this, ICC1 is measured on condition that addresses are changed only one time during tCK (MIN.).
o 2. ICC4 depends on output loading and cycle rates. Specified values are obtained with the output open. In
addition to this, ICC4 is measured on condition that addresses are changed only one time during tCK (MIN.).
duct 3. ICC5 is measured on condition that addresses are changed only one time during tCK (MIN.).
6
Data Sheet E0280N10 (Ver 1.0)

Share Link: 