High Level Termination Insensitive Mixer,
1 - 3500 MHz
MD-/MDS-189
V4
Electrical Specifications1: TA = -55°C to +85°C
Frequency: RF, LO Ports = 1-3500 MHz, IF Port = 5-1500 MHz
Parameter
Conversion Loss
Isolation
Test Conditions
LO @ 23 dBm
IF @ 60 MHz
LO to RF
Frequency
Units
Min
Typ
Max
5 - 1000 MHz
dB
1000 - 3000 MHz
dB
1 - 3500 MHz
dB
1 - 2000 MHz
dB
2000 - 3500 MHz
dB
—
6.5
7.0
—
7.5
8.5
—
8.0
9.5
30
35
—
25
30
—
LO to IF
1 - 2000 MHz
dB
25
30
—
2000 - 3500 MHz
dB
20
25
—
RF to IF
10 - 500 MHz
1 - 3500 MHz
dB
30
35
—
dB
15
20
—
Input Compression
(1 dB)
IIP3
Desensitivity (1dB)
LO @ 23 dBm
IF @ 60 MHz
LO @ 23 dBm
IF @ 60 MHz
LO @ 23 dBm
IF @ 60 MHz
—
—
—
+20
—
—
dBm
—
+28
—
—
dBm
—
+17
—
—
dBm
—
—
SSB Noise Figure
LO @ 23 dBm
—
IF @ 60 MHz
Within 1 dB of Conversion Loss
Max
—
—
—
—
Bottom View of SF-1
Typical Performance Curves
.385 Ref
4X .016 ± .002
.506
.220
.381
.165
.002
.000
2
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.