MIC281
Slave Address
The MIC281 will only respond to its own unique slave ad-
dress. A match between the MIC281’s address and the
address specified in the serial bit stream must be made to
initiate communication. The MIC281’s slave address is fixed
at the time of manufacture. Eight different slave addresses
are available as determined by the part number. See Table
2 below and the Ordering Information table.
Part Number
Slave Address
MIC281-0BM6
1001 000xb = 90h
MIC281-1BM6
1001 001xb = 92h
MIC281-2BM6
1001 010xb = 94h
MIC281-3BM6
1001 011xb = 96h
MIC281-4BM6
1001 100xb = 98h
MIC281-5BM6
1001 101xb = 9Ah
MIC281-6BM6
1001 110xb = 9Ch
MIC281-7BM6
1001 111xb = 9Eh
Table 2. MIC281 Slave Addresses
Temperature Data Format
The least-significant bit of the temperature register represents
one degree Centigrade. The values are in a two’s comple-
ment format, wherein the most significant bit (D7) represents
the sign: zero for positive temperatures and one for negative
temperatures. Table 3 shows examples of the data format
used by the MIC281 for temperatures.
Micrel
Temperature
Binary
Hex
+127°C
0111 1111
7F
+125°C
0111 1101
7D
+25°C
0001 1001
19
+1°C
0000 0001
01
0°C
0000 0000
00
–1°C
1111 1111
FF
–25°C
1110 0111
E7
–125°C
1000 0011
83
–128°C
1000 0000
80
Table 3. Digital Temperature Format
Diode Faults
The MIC281 is designed to respond in a failsafe manner to
diode faults. If an internal or external fault occurs in the tem-
perature sensing circuitry, such as T1 being open or shorted
to VDD or GND, the temperature result will be reported as the
maximum full-scale value, +127°C. Note that diode faults will
not be detected until the first A/D conversion cycle is completed
following power-up or exiting shutdown mode.
Shutdown Mode
Setting the shutdown bit in the configuration register will
cause the MIC281 to cease operation. The A/D converter will
stop and power consumption will drop to the ISHDN level. No
registers will be affected by entering shutdown mode. The
last temperature reading will persist in the TEMP register.