DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

4N600 查看數據表(PDF) - Bay Linear

零件编号
产品描述 (功能)
生产厂家
4N600 Datasheet PDF : 2 Pages
1 2
4N600(3600)
Electrical Characteristics ( TC = 25°C unless otherwise specified)
Symbol
Parameter
Conditions
Min
IDSS
Zero Gate Voltage Drain Current
VDS=600V
VGS=0V
V
Drain-to-Source Breakdown
ID=100µA, VGS=0
600
VGS(TH)
Gate Threshold Voltage
VDS=VGS
ID=250µA
2
Typ
-
RDS(ON)
Static Drain Voltage
VGS=10V, ID=2.4A
-
-
IGSS
gfs
CISS
COSS
CRSS
tD(ON)
tr
td(off)
tF
IS
Gate-to-Source Forward Leakage VGS=20V
Gate-to-Source Reverse Leakage VGS=-20V
Forward Tranconductance
VDS=100V, ID =2.4A
Input Capacitance
Output Capacitance
Reverse Tras. Capacitance
VDS= 25V, VGS=0V
F=1.0 MHZ
Turn-ON Delay Time
Turn-ON Rise Time
Turn-OFF Delay Time
Turn-OFF Fall Time
VDD=300V
ID=2.4A, RGEN=12
RD=74
Maxim Continuous Drain source Diode Forward Current
VDS (note)
Drain Source Diode
Forward Voltage
VGS=0V
IS=4A
THERMAI CHRACTERISTICS
RJC
Thermal Resistance, Junction to Case
RJC
Thermal Resistance, Junction to Ambient
2.9
800
110
20
12
18
53
19
Max
100
-
4
1.9
100
-100
4.0
1.50
5
100
Units
µA
V
V
NA
S
pF
pF
pF
NS
A
V
°C/W
°C/W
Note: Pulse Test: Pulse With300 µS, Duty Cycle 2.0%
Advance Information- These data sheets contain descriptions of products that are in development. The specifications are based on the engineering calculations,
computer simulations and/ or initial prototype evaluation.
Preliminary Information- These data sheets contain minimum and maximum specifications that are based on the initial device characterizations. These limits are
subject to change upon the completion of the full characterization over the specified temperature and supply voltage ranges.
The application circuit examples are only to explain the representative applications of the devices and are not intended to guarantee any circuit
design or permit any industrial property right to other rights to execute. Bay Linear takes no responsibility for any problems related to any
industrial property right resulting from the use of the contents shown in the data book. Typical parameters can and do vary in different
applications. Customer’s technical experts must validate all operating parameters including “ Typical” for each customer application.
LIFE SUPPORT AND NUCLEAR POLICY
Bay Linear products are not authorized for and should not be used within life support systems which are intended for surgical
implants into the body to support or sustain life, in aircraft, space equipment, submarine, or nuclear facility applications without
the specific written consent of Bay Linear President.
Bay Linear, Inc 2478 Armstrong Street, Livermore, CA 94550 Tel: (925) 989-7144, Fax: (925) 940-9556
www.baylinear.com

Share Link: 