MLX90269
Absolute Integrated Pressure Sensor
7. Performance Graphs
The graphs below show measured output voltages (on a 4 Bar full scale sensor) taken at 15 pressure
points (500 mBar to 4000 mBar), at 21 ambient temperature points (-50 to 150 Celsius) and with Vdd set
to 4.5 V, 5 V and 5.5 V.
100
90
80
70
60
50
40
30
20
10
0
0
Vout versus Pressure with Ta = -50..150 C
10
20
30
40
50
60
70
80
90
100
Pressure %FS (FS = 4000 mBar)
Note : FS means Output Voltage Full Scale (4 V).
Measured Error is below 1 % of FS for all ambient temperature and pressure points (see graphs below).
Error versus Ambient Temperature with P = 500..4000 mBar
1.5
1
0.5
0
-0.5
-1
-1.5
-50
-30
-10
10
30
50
70
90
110
130
150
Ambient Temperature C
3901090269
Rev. 006
Page 5 of 9
Data Sheet
Mar/08