NL10276AC30-01A
POWER SUPPLY SEQUENCE
There is no sequence among the synchronous signals, the video signals and the power supply. However, 12 V
for backlight should be started up within 80 ms, otherwise, the protection circuit makes the backlight turns off.
Please note that the supply voltage must not be applied while the control signals (SEL, UP, DOWN and RESET)
are connected to GND. Otherwise the module may cause malfunctions.
If the power supply voltage is applied while SEL and RESET is connected to GND, the mode is set into NEC
factory mode. In this case, both LEDON and LEDOFF become “H”. Please do not use the module in this mode
which may write over the default value. Please turn off the power supply immediately and turn on the power while
SEL and RESET are connected to GND again. If the default value has been revised by accident, please follow the
instruction below.
<NEC factory mode>
This mode can control Brightness and Contrast and OSD position. Factory Reset function is reset all values. But
do not use the module in this mode which may write over the default values affect to the LCD internal operation.
Please turn off the power immediately and turn on the power while SEL and RESET are connected to GND again.
If the default value has been revised by accident, please select “Factory Reset” mode and press “Reset” key for
over two seconds.
Functions
Brightness
Contrast
LCD Data
Color adjust
VCO
HDTV Select
OSD position
Factory Reset
RESET
Control contents
Total Brightness and Sub Brightness for each RGB
Total Contrast and Sub Contrast for each RGB
Never select and adjust values
Change the OSD display position
Above function values is reset to factory values.
RESET the NEC factory mode
How to reset
Press RESET key over 2 seconds
Press RESET key over 2 seconds
Please go to the Factory reset.
Press Reset key over 2 seconds.