NLAS3699
DC CHARACTERISTICS − Digital Section (Voltages Referenced to GND)
Guaranteed Limit
Symbol
VIH
Parameter
Minimum High−Level Input
Voltage, Select Inputs
Condition
VCC
*405C to 255C t855C Unit
1.8
1.2
1.2
V
2.5
1.7
1.7
3.6
2.2
2.2
VIL
Maximum Low−Level Input
Voltage, Select Inputs
1.8
0.4
0.4
V
2.5
0.5
0.5
3.6
0.7
0.7
IIN
Maximum Input Leakage
VIN = VCC or GND
Current, Select Inputs
3.6
$0.1
$1.0
mA
IOFF
Power Off Leakage Current VIN = VCC or GND
ICC
Maximum Quiescent Supply Select and VIS = VCC or GND
Current (Note 2)
0
1.65 to 3.6
$0.5
$1.0
$2.0
mA
$2.0
mA
DC ELECTRICAL CHARACTERISTICS − Analog Section
Guaranteed Maximum Limit
−405C to 255C
t855C
Symbol
RON
Parameter
NC/NO On−Resistance
(Note 2)
RFLAT
NC/NO On−Resistance Flatness
(Notes 2, 4)
Condition
VCC
VIN v VIL or VIN w VIH
2.5
VIS = GND to VCC
3.0
IINI v 100 mA
3.6
ICOM = 100 mA
2.5
VIS = 0 to VCC
3.0
3.6
Min Max Min Max Unit
0.65
0.75 W
0.6
0.75
0.55
0.7
0.15
0.15 W
0.15
0.15
0.15
0.15
DRON
On−Resistance Match Between Channels VIS = 1.3 V;
2.5
(Notes 2 and 3)
ICOM = 100 mA
VIS = 1.5 V;
3.0
ICOM = 100 mA
VIS = 1.8 V;
3.6
ICOM = 100 mA
0.06
0.06 W
0.05
0.05
0.05
0.05
INC(OFF) NC or NO Off Leakage Current (Note 2)
INO(OFF)
VIN = VIL or VIH
VNO or VNC = 0.3 V
VCOM = 3.3 V
3.6
−5.0 5.0 −10 10 nA
ICOM(ON)
COM ON
Leakage Current
(Note 2)
VIN = VIL or VIH
3.6
VNO 0.3 V or 3.3 V with
VNC floating or
VNC 0.3 V or 3.3 V with
VNO floating
VCOM = 0.3 V or 3.3 V
−10 10 −100 100 nA
2. Guaranteed by design. Resistance measurements do not include test circuit or package resistance.
3. DRON = RON(MAX) − RON(MIN) between nS1 or nS2.
4. Flatness is defined as the difference between the maximum and minimum value of on−resistance as measured over the specified analog
signal ranges.
http://onsemi.com
4