DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

PA60 查看數據表(PDF) - Cirrus Logic

零件编号
产品描述 (功能)
生产厂家
PA60 Datasheet PDF : 4 Pages
1 2 3 4
PA60
Product Innova tionFrom
GENERAL
Please read Application Note 1 "General Operating Consider-
ations" which covers stability, supplies, heatsinking, mounting,
SOA interpretation, and specification interpretation.Visit www.
Cirrus.com for design tools that help automate tasks such as
calculations for stability, internal power dissipation, heatsink
selection;Apex's complete Application Notes library;Technical
Seminar Workbook; and Evaluation Kits.
STABILITY CONSIDERATIONS
All monolithic power op
amps use output stage
+
topologies that present
special stability problems.
This is primarily due to
non-complementary (both
CSN
0.01µF
devices are NPN) output
stages with a mismatch in
RSN
gain and phase response
10Ω
for different polarities of
output current. It is difficult
for the op amp manufacturer
to optimize compensation
FIGURE 4. R-C Snubber
for all operating conditions. For applications with load current
exceeding 300mA, oscillation may appear. The oscillation may
occur only with the output voltage swing at the negative or
positive half cycle. Under most operating and load conditions
acceptable stability can be achieved by providing a series RC
snubber network connected from the output to ground (see
Figure 4). The recommended component values of the of the
network are,RSN = 10Ω and CSN = 0.01µF. Please refer to Ap-
plication Note 1 for further details.
SAFE OPERATING AREA (SOA)
The SOA curves combine the effect of all limits for this power
op amp. For a given application, the direction and magnitude
of the output current should be calculated or measured and
checked against the SOA curves. This is simple for resistive
loads but more complex for reactive and EMF generating loads.
The following guidelines may save extensive analytical efforts.
THERMAL CONSIDERATIONS
The PA60EU has a large exposed copper heat tab to which
the monolithic is directly attached. The PA60EU may require a
thermal washer, which is electrically insulating since the tab
is directly tied to -VS. This can result in a thermal impedance
RCS of up to 1˚C/W or greater.
SOA PA60EU
10
(A+B) AMPLIFIERS LOADED
(A) AMPLIFIER LOADED
1
DC, TC = 25°C
DC, TC = 85°C
0.1
1
10
100
SUPPLY TO OUTPUT DIFFERENTIAL VOLTAGE, VS - VO, (V)
POWER DERATING
35
30
(A+B) AMPLIFIERS
25
20
15
10
(A) AMPLIFIER
5
0
0
25
50
75
100
125
CASE TEMPERATURE, T C (C)
MOUNTING PRECAUTIONS
1. Always use a heat sink. Even unloaded the PA60EU can
dissipate up to .4 watts.
2. Avoid bending the leads. Such action can lead to internal
damage.
3. Always fasten the tab of the EU package to the heat sink
before the leads are soldered to fixed terminals.
4. Strain relief must be provided if there is any probability of
axial stress to the leads.
4
PA60U

Share Link: 