RE46C121
CMOS Ionization Smoke Detector ASIC with Interconnect
Product Specification
R&E International
DEVICE DESCRIPTION and APPLICATION NOTES
Note: All timing references are nominal values. Refer to the electrical specifications for limits
Internal Timing – With external components as indicated on the application drawing the period of the
oscillator is nominally 1.67 seconds in standby. Every 1.66 seconds the detection circuitry is powered up
for 10.5mS and the status of the smoke comparator is latched. In addition every 40 seconds the LED
driver is turned on for 10.5mS and the status of the low battery comparator is latched. The smoke
comparator status is not checked during the low battery test, during the low battery horn warning chirp, or
when the horn is on due to an alarm condition.
If an alarm condition is detected the oscillator period increases to 41.5mS.
Due to the low currents used in the oscillator the capacitor on pin 12 should be a low leakage type.
Oscillator accuracy will depend mainly on the tolerance of the RBIAS resistor and OSCAP capacitor.
Smoke Detection Circuit – The smoke comparator compares the ionization chamber voltage to a voltage
derived from a resistor divider across VDD. This divider voltage is available externally on pin 13 (VSEN).
Pin 13 (VSEN) can be used to modify the internal set point for the smoke comparator by using external
resistors to VDD or VSS. Nominal values for the internal resistor divider are indicated on the block
diagram. These internal resistor values can vary by up to ±20% but the resistor matching will be <2% on
any one device. A transmission switch on pin 13 isolates this pin during the low battery test so that the
low battery set point will not be affected if external resistors are used to modify the smoke sensitivity set
point.
The guard amplifier and outputs are always active and will be within 50mV of the DETECT input to
reduce surface leakage. The guard outputs also allow for measurement of the DETECT input without
loading the ionization chamber.
Low Battery Detection - An internal reference is compared to the voltage divided VDD supply. The battery
can be checked under load via the LED low side driver output since low battery status is latched at the
end of the 11mS LED pulse. Pin 3 (LBADJ) can be used to modify the low battery set point by placing a
resistor to VDD or VSS. Note that the internal resistor string is common to both pin 3 and pin 13 so there
will be some interaction between the two. Modification of the low battery set point may affect the smoke
sensitivity setting.
LED Pulse – The LED is pulsed on for 10.5mS every 40S in standby. In alarm the LED is pulsed on for
10.5mS every 1S. For a remote alarm condition the LED is always off.
Interconnect – Pin 2 (IO) provides the capability to common many detectors in a single system. If a single
unit goes into alarm the IO pin is driven high. This high signal causes the interconnected units to alarm.
The LED flashes every 1S for 10.5mS on the signaling unit and is inhibited on the units that are in alarm
due to the IO signal. An internal sink device on the IO pin helps to discharge the interconnect line. This
dump device is active for 1 clock cycle after the unit exits the alarm condition (1.67S).
The interconnect input has a 500mS nominal digital filter. This allows for interconnection to other types of
alarms (carbon monoxide for example) that may have a pulsed interconnect signal.
Testing - By holding pin 12 (OSCAP) low the internal power strobe is active and pin1 (DETCOMP) can be
used to check for smoke. Please refer to the timing diagrams.