, Features
Unregulated
Converters
Custom Solutions Available
1kVDC Isolation
No External Components Required
Optional Continuous Short Circuit Protected
UL94V-0 Package Material
No Heatsink Required
Efficiency to 87%
ECONOLINE
DC/DC-Converter
RI
Series
Selection Guide
Part
Number
Input
Voltage
Output
Voltage
Output
Current
SIP4
(VDC)
(VDC)
(mA)
RI-xx3.3S
5, 9, 12, 15, 24
3.3
606
RI-xx05S
5, 9, 12, 15, 24
5
400
RI-xx07S
5, 9, 12, 15, 24
7
285
RI-xx09S
5, 9, 12, 15, 24
9
222
RI-xx12S
5, 9, 12, 15, 24
12
167
RI-xx15S
5, 9, 12, 15, 24
15
133
RI-xx24S
5, 9, 12, 15, 24
24
83
xx = Input Voltage
* add Suffix “P” for Continuous Short Circuit Protection, e.g. RI-0505S/P
Efficiency
(%)
70-75
78-83
78-83
78-83
80-85
80-85
80-87
2 Watt
SIP4
Single Output
Specifications (Core Operating Area)
Input Voltage Range
±10%
Output Voltage Accuracy
±5%
Line Voltage Regulation
Load Voltage Regulation
(10% to 100% full load)
3.3V output types
5V, output type
9V, 12V, 15V, 24V output types
1.2%/1% of Vin typ.
20% max.
15% max.
10% max.
Output Ripple and Noise (20MHz limited)
200mVp-p max.
Operating Frequency
35kHz min. / 50kHz typ. / 85kHz max.
Efficiency at Full Load
70% min. / 80% typ.
No Load Power Consumption
Isolation Voltage
Rated Working Voltage
142mW min. / 185mW typ. / 252mW max.
(tested for 1 second)
1000VDC min.
(long term isolation)
see Application Notes
Isolation Capacitance
Isolation Resistance
Short Circuit Protection
P-Suffix
30pF min. / 85pF max.
10 Gmin.
1 Second
Continuous
Operating Temperature Range (free air convection)
-40°C to +85°C (see Graph)
Storage Temperature Range
-55°C to +125°C
Relative Humidity
95% RH
Package Weight
} MTBF (+25°C) Detailed Information see
(+85°C) Application Notes chapter "MTBF"
using MIL-HDBK 217F
using MIL-HDBK 217F
1.4g
845 x 103 hours
160 x 103 hours
70
July-2006
Derating-Graph
(Ambient Temperature)
100
80
60 Safe Operating Area
40
20
0
-40
0
50
100 150
85
Operating Temperature °C
www.recom-international.com