DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

SN74LS377N 查看數據表(PDF) - ON Semiconductor

零件编号
产品描述 (功能)
生产厂家
SN74LS377N
ON-Semiconductor
ON Semiconductor ON-Semiconductor
SN74LS377N Datasheet PDF : 8 Pages
1 2 3 4 5 6 7 8
SN74LS377
DC CHARACTERISTICS OVER OPERATING TEMPERATURE RANGE (unless otherwise specified)
Limits
Symbol
Parameter
Min Typ Max Unit
Test Conditions
VIH
Input HIGH Voltage
2.0
V
Guaranteed Input HIGH Voltage for
All Inputs
VIL
Input LOW Voltage
0.8
Guaranteed Input LOW Voltage for
V
All Inputs
VIK
Input Clamp Diode Voltage
– 0.65 – 1.5
V
VCC = MIN, IIN = – 18 mA
VOH
Output HIGH Voltage
2.7
3.5
V
VCC = MIN, IOH = MAX, VIN = VIH
or VIL per Truth Table
VOL
Output LOW Voltage
0.25 0.4
0.35 0.5
V
IOL = 4.0 mA
V
IOL = 8.0 mA
VCC = VCC MIN,
VIN = VIL or VIH
per Truth Table
IIH
Input HIGH Current
20
µA VCC = MAX, VIN = 2.7 V
0.1
mA VCC = MAX, VIN = 7.0 V
IIL
Input LOW Current
– 0.4 mA VCC = MAX, VIN = 0.4 V
IOS
Short Circuit Current (Note 1)
– 20
– 100 mA VCC = MAX
ICC
Power Supply Current
28
mA VCC = MAX, NOTE 1
NOTE: With all inputs open and GND applied to all data and enable inputs, ICC is measured after a momentary GND, then 4.5 V is applied to clock.
Note 1: Not more than one output should be shorted at a time, nor for more than 1 second.
AC CHARACTERISTICS (TA = 25°C, VCC = 5.0 V)
Limits
Symbol
Parameter
Min Typ Max
fMAX
tPLH
tPHL
Maximum Clock Frequency
Propagation Delay,
Clock to Output
30
40
17
27
18
27
Unit
MHz
ns
Test Conditions
VCC = 5.0 V
CL = 15 pF
AC SETUP REQUIREMENTS (TA = 25°C, VCC = 5.0 V)
Limits
Symbol
Parameter
Min
Typ
Max
Unit
tW
Any Pulse Width
20
ns
ts
Data Setup Time
20
ns
ts
Enable Setup
Inactive — State
10
Time
Active — State
25
ns
ns
th
Any Hold Time
5.0
ns
Test Conditions
VCC = 5.0 V
DEFINITION OF TERMS
SETUP TIME (ts) — is defined as the minimum time
required for the correct logic level to be present at the logic
input prior to the clock transition from LOW-to-HIGH in
order to be recognized and transferred to the outputs.
HOLD TIME (th) — is defined as the minimum time
following the clock transition from LOW-to-HIGH that the
logic level must be maintained at the input in order to ensure
continued recognition. A negative HOLD TIME indicates
that the correct logic level may be released prior to the clock
transition from LOW-to-HIGH and still be recognized.
http://onsemi.com
3

Share Link: 