AC Test Conditions
Input Pulse Levels ....................................................0V to 3V
Input Rise and Fall Times ................................................. ≤ 5 ns
Input and Output Timing Reference Levels .................... 1.5V
Output Load..................................See Figure 4 and Figure 5
Capacitance
(TA = 25°C, f = 1.0 MHz)
Symbol
Parameter[2]
CIN
COUT
Input Capacitance
Output Capacitance
Max Units
7 pF
7 pF
Conditions
ΔV = 0 to 3V
ΔV = 0 to 3V
Figure 4. AC Output Loading
OUTPUT
789 Ohms
3.0V
577 Ohms
30 pF
INCLUDING
SCOPE AND
FIXTURE
Figure 5. AC Output Loading for Tristate Specifications
(tHZ, tLZ, tWLQZ, tWHQZ, tGLQX, tGHQZ)
3.0V
OUTPUT
789 Ohms
577 Ohms
5 pF
INCLUDING
SCOPE AND
FIXTURE
STK14CA8
Note
2. These parameters are guaranteed but not tested.
Document Number: 001-51592 Rev. **