DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

TDA8559 查看數據表(PDF) - Philips Electronics

零件编号
产品描述 (功能)
生产厂家
TDA8559
Philips
Philips Electronics Philips
TDA8559 Datasheet PDF : 32 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Philips Semiconductors
Low-voltage stereo headphone amplifier
Product specification
TDA8559
SYMBOL
PARAMETER
CONDITIONS
MIN. TYP. MAX. UNIT
Single-ended stereo application (RL = 32 )
Po
THD
output power
total harmonic distortion
Gv
fss
αcs
∆Gv
Vno
Vno(mute)
Vo(mute)
Vmt
Zi
Vos
SVRR
voltage gain
small signal roll-off frequency
channel separation
channel unbalance
noise output voltage
noise output voltage in mute
output voltage in mute
mid-tap voltage
input impedance
DC output offset voltage
supply voltage ripple rejection
THD = 10%
30
Po = 20 mW; fi = 1 kHz; note 2
Po = 20 mW; fi = 10 kHz; note 2
25
1 dB
Rs = 5 k
40
note 3
note 3
note 4
1.4
75
note 5
note 6
45
35
mW
0.075 0.15 %
0.1
%
26
27
dB
750
kHz
dB
1
dB
70
85
µV
20
30
µV
30
µV
1.5
1.6
V
100 125 k
100 mV
55
dB
BTL application (RL = 25 )
Po
output power
THD = 10%
125 140
mW
THD
total harmonic distortion
Po = 70 mW; fi = 1 kHz; note
0.05 0.1
%
Po = 70 mW; fi = 10 kHz; note 2
0.1
%
Gv
voltage gain
31
32
33
dB
fss
small signal roll-off frequency
1 dB
750
kHz
Vno
noise output voltage
note 3
100 120 µV
Vno(mute) noise output voltage in mute
note 3
25
40
µV
Vo(mute) output voltage in mute
note 4
40
µV
Vos
DC output offset voltage
note 7
150 mv
SVRR supply voltage ripple rejection note 6
39
49
dB
Zi
input impedance
39
50
61
k
Line driver application (RL 1 k)
Vo
line output voltage
0.1
2.9
V
Notes
1. The supply voltage range at pin VP1 is from 1.9 to 18 V. Pin VP2 is used for the voltage range from 6 to 30 V.
2. Measured with low-pass filter 30 kHz.
3. Noise output voltage measured with a bandwidth of 20 Hz to 20 kHz, unweighted. Rs = 5 k.
4. RMS output voltage in mute is measured with Vi = 200 mV (RMS); f = 1 kHz.
5. DC output offset voltage is measured between the signal output and the 0.5VP output.
6. The ripple rejection is measured with a ripple voltage of 200 mV (RMS) applied to the positive supply rail (Rs = 0 k).
7. DC output offset voltage is measured between the two signal outputs.
1997 Jun 27
7