3½ D I G I T , L E D D I S P L A Y , A C A M M E T E R S
ACA-20PC Series
access the recessed calibration potentiometer located on the back of
the meter (see Mechanical Specifications). Contact DATEL if additional
information is required regarding calibration, setup, or any other
technical issue pertaining to the ACA-20PC.
3. Wire Gauges and Fusing: Wires specified in the Functional Specifica-
tions section must be used for making connections to ACA-20PC
Series ammeters. All power-supply and load wiring must be rated for
the supply voltages and currents they will conduct and must comply
with any code or application-mandated requirements pertaining to the
user’s specific installation.
In particular, special attention must be paid to ACA-20PC-1-AC1-RL
and ACA-20PC-2-AC1-RL ac-powered models when their built-in
auxiliary terminal block connections (TB1) are used to supply current to
an external load. The supply wires connected to both the meter and the
load must be fused according to the current rating of the wire gauge
being used, in accordance with applicable regulatory codes. Also, wire
insulation should be stripped to within ±10% of the stated dimensions,
and wires should be inserted into TB1 such that their insulation is not
pinched by the screw terminal.
The ACA-20PC-3-ACX (0-50A range, ac-powered) and ACA-20PC-4-
ACX (0-100A, ac-powered) models’ TB1 is used only for powering the
meters' internal circuitry. It must not be used to supply current to
external loads. The supply wires feeding these meters must also be
fused according to the current rating of the wire gauge being used, in
accordance with applicable regulatory codes.
AC-powered models draw minimal steady-state supply currents (50mA
max.), and in most applications, they can be fused according to the
supply wire’s maximum amperage rating. However, these models can
draw significantly higher surge currents for brief periods when the ac
line voltage is initially applied.
Panel Installation
All connections to ACA-20PC Series ammeters must be made after
the ammeter is securely attached to the panel and with all load and
supply voltages de-energized (off).
Care should be exercised when passing the load-carrying conductor
through the meter’s built-in CT—particularly when larger-gauge
conductors are used. The position of the installed wire should be such
that minimal forces are applied to the built-in CT, TB1, or to the ammeter
itself. In high-vibration environments, adequate strain reliefs be used for
all load and supply wiring.
To ensure a secure panel-mount installation, DATEL recommends using
Step 1.
Step 2.
PANEL
PANEL
1
2
4. AC Supply Polarity and Grounding: The two ac supply inputs, TB1-A
and TB1-B, on ac-powered ammeters are not in themselves polarity
sensitive, that is, they have no internal "AC LO" or "AC HI" designa-
tions. Also, ac-powered ACA-20PC ammeters do not include or require
a connection to earth/chassis ground. However, in many applications,
external ac loads which are connected directly to the ACA-20PC’s built-
in auxiliary terminal blocks must be wired with proper polarity and
connected to earth/chassis ground.
5. Connector Torque Ratings: It is important to tighten TB1's screw
terminals to their rated torque specifications of 4.4 pound-inches
(0.5Nm) for four-terminal ammeters (ACA-20PC-1-AC1-RL and ACA-
20PC-2-AC1-RL), and 3.6 pound-inches (0.4Nm) for two-terminal
ammeters. Proper tightening will minimize connector losses and ensure
safe, reliable operation.
6. 100 Amp Model (ACA-20PC-4-XXX): This model’s built-in current
transformer requires a larger panel cutout width dimension. See
Mechanical Specifications for more information.
7. DC-Powered Models: DC-powered models draw minimal supply
currents (120mA max.) and in most applications can be fused according
to the supply wire’s maximum amperage rating. However, be sure to
check and comply with all applicable codes and regulations to ensure
proper installation and operation.
8. Isolation: The on-board CT (L1) provides a minimum 2000Vdc isolation
between the current-carrying conductor passing through its primary
circuit and the ammeter supply voltage connected to TB1. Of course,
this isolation rating only applies to applications in which the load wiring
(i.e., the wire passing through the CT’s center hole) does not connect
directly or indirectly to TB1-A or TB1-B.
the DMS-BZL4 bezel assembly (with sealing gasket) supplied with each
ammeter. Also, please note that the ACA-20PC-4-XXX 100A oversize
CT requires a larger panel-cutout width of 1.350" (34.3mm). See
Mechanical Specifications for detailed cutout and ammeter dimensions.
Following the four-step sequence shown in Figure 2 below— being careful
not to apply excessive force or twisting motions—insert the ammeter into
the panel opening. When using the DMS-BZL4 bezel assembly, install its
sealing gasket so it is positioned between the ammeter’s front flange and
panel front surface (see Mechanical Specifications). Be sure to use and
securely tighten all four screws supplied with the bezel assembly.
Step 3.
PANEL
3
Step 4.
PANEL
BEZEL
4
Figure 2. Panel Installation
GASKET
(optional)
DATEL, Inc., Mansfield, MA 02048 (USA) Tel: (508)339-3000, (800)233-2765 Fax: (508)339-6356 E–mail: sales@datel.com Internet: www.datel.com