TS1582
3A Dual Input LDO
Application Information (Continue)
Grounding and Output Sensing
The TS1582 allows true Kelvin sensing for both the high & low side of the load. A result the voltage regulation at the
load can be easily optimized. Voltage drops due to parasitic resistances between the regulator and the load can be
placed inside the regulation loop. The advantages of remote sensing are illustrated in Figure 1 through 3.
Figure 1 show the device connected as a conventional 3 terminal regulator with the Sense lead connected directly to
the output of the device. Rp is the parasitic resistance of the connections between the device and the load. Trace A of
Figure 3 illustrates the effect of Rp.
Figure 2 show the device connected to take advantage of the remote sense feature. The Sense Pin and the top of the
resistor divider are connected to the top of the load; the bottom of the resistor divider is connected to the bottom of the
load.
Figure 1. Conventional Load Sensing
Figure 2. Remote Load Sensing
The effect on output regulation can be seen in trace B of Figure 3. It is important to note that the voltage drops due to
Rp are not eliminated; they will add to the dropout voltage of the regulator regardless. The TS1582 can control the
voltage at the load as long as the input-output voltage is greater than the total of the dropout voltage of the device plus
the voltage drop across Rp
Figure 3. Remote Sensing Improves Load
Regulation
Figure 4. Illustrates there transient effects