DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

AD9805 查看數據表(PDF) - Analog Devices

零件编号
产品描述 (功能)
生产厂家
AD9805 Datasheet PDF : 24 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
Power-On Initialization and Calibration Sequence
When the AD9807/AD9805 is powered on, the following
sequence should be used to initialize the part to a known state.
The digital gain and offset buses are disabled until the calibra-
tion sequence. The Bayer mode register must be written to and
set to zero if this mode is not going to be used.
CHANGE
POINTER
WRITE TO CONFIGURATION REGISTER
SET DIGITAL GAIN RANGE TO 000
SET GAIN/OFFSET BUS SIZE TO 000
SET COLOR POINTER
AD9807/AD9805
To calibrate the AD9807/AD9805 for a particular scan, use the
following sequence.
SET PGA GAIN(S)
(INPUT OFFSET = 0mV)
SCAN DARK LINE
COMPUTE PIXEL OFFSETS
WRITE TO PGA GAIN REGISTER
SET TO GAIN OF ONE (0000)
WRITE TO INPUT OFFSET REGISTER
SET TO 0mV (11001100)
SET INPUT OFFSET
SET ODD/EVEN OFFSET
YES
SET
ANOTHER
COLOR
?
NO
WRITE TO CONFIGURATION 2 REGISTER
SET CDS OR SHA OPERATION
SET 3-CHANNEL OR 1-CHANNEL MODE
SET ADC FULL-SCALE RANGE
SET CLAMP MODE
WRITE TO BAYER MODE REGISTER
SET MODE ON OR OFF
OPTIONAL READBACK
FROM REGISTERS
Figure 19. Initialization
YES
SET
ANOTHER
COLOR
?
NO
SET GAIN/OFFSET BUS SIZE
SET EXTERNAL PIXEL OFFSET VECTORS
SCAN WHITE LINE
COMPUTE PIXEL GAINS
YES
ADJUST
PGA GAIN(S)
?
NO
SET DIGITAL GAIN RANGE
Figure 20. Calibration
REV. 0
–19–

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]