DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

UR7HCPXZ-P440 查看數據表(PDF) - Semtech Corporation

零件编号
产品描述 (功能)
生产厂家
UR7HCPXZ-P440 Datasheet PDF : 12 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
PS/2 MODE COMMANDS
When the Reset Command (FFh)
is received, the UR7HCPXZ-P440
sets the following default
parameters: Incremental Stream
Mode, 1:1 scaling, report rate of
100 Hz, and disabled. It then
sends AAh to the host followed by
a device ID of 00h.
The host sends the Resend Last
Data Stream Command (FEh) when
it detects an error in any
UR7HCPXZ-P440 transmission.
The device then resends the last
output data packet to the host.
This transmission occurs after a
PixiPointTM Z transmission and
before the host enables the
interface allowing the next
PixiPointTM Z output.
The Set Default Status
Command (F6h) re-initializes the
device to its condition at power-up.
The Disable Command (F5h)
stops the device from transmitting
all reports. However, the mode
does not change; the PixiPointTM Z
is still able to respond to
commands. If the Disable
Command is issued while the
device is transmitting a report, the
UR7HCPXZ-P440 immediately
stops the transmission and
disables itself.
The Reset Echo Mode Command
(ECh) returns the device to its
previous mode, and disabled.
The Set Prompt (Remote) Mode
Command (F0h) sets the device
to Prompt Mode. Data values are
then only reported in response to a
Read Report Command (EBh).
If the Set Echo Mode Command
(EEh) is received, the PixiPointTM Z
will immediately return any data
bytes except FFh or ECh.
If the PixiPointTM Z is in Incremental
Stream Mode, the Enable
Command (F4h) will allow it to
begin data transmission. If the
device is in Prompt Mode, the
Enable Command will only update
the internal status of the PixiPointTM
Z.
The PixiPointTM Z will respond to the
Set Sampling Rate Command
(F3h) in both Stream and Prompt
Modes but will only update its
internal status if this command is
enacted while the device is in the
Stream Mode.
The UR7HCPXZ-P440 responds to
the Read Device Type Command
(F2h) with the device ID of 00h.
The Read Report Command
(EBh) prompts the PixiPointTM Z for
a report. The report occurs even if
the device has not moved or if the
status of the switches did not
change.
The Set Incremental Stream
Mode Command (EAh) sets the
PixiPointTM Z to Stream Mode and
disables the device.
The Status Request Command
(E9h) returns a 3-byte status
report.
The Set Resolution Command
(E8h) controls resolution, the Set
2:1 Scaling Command (E7h)
enables a coarse/fine tracking
response, and the Set 1:1 Scaling
Command (E6h) enables the
values of movements to be
transmitted to the host without any
scaling. Due to Semtechs
Advanced Motion Algorithm, Set
Resolution and Scaling Commands
are acknowledged and reported as
activated, but their status is
ignored.
Copyright Semtech 2000-2001
6
DOC7-PXZ-P440-DS-111
www.semtech.com