AD10265
ABSOLUTE MAXIMUM RATINGS1
Table I. Output Coding
Parameter
Min Max Unit
MSB
LSB
Base 10
Input
ELECTRICAL
VCC Voltage
0
VEE Voltage
–7
Analog Input Voltage
VEE
Analog Input Current
–10
Digital Input Voltage (ENCODE)
0
ENCODE, ENCODE Differential Voltage
+7 V
0V
VCC V
+10 mA
AVCC V
4V
0111111111111
0000000000001
0000000000000
1111111111111
1000000000000
2047
+1
0
–1
2048
+FS
0.0 V
–FS
Digital Output Current
–10 +10 mA
EXPLANATION OF TEST LEVELS
ENVIRONMENTAL2
Test Level
Operating Temperature (Case)
–55 +125 °C
I. 100% production tested.
OBSOLETE Maximum Junction Temperature
Lead Temperature (Soldering, 10 sec)
Storage Temperature Range (Ambient)
175 °C
300 °C
–65 +150 °C
NOTES
1Absolute maximum ratings are limiting values to be applied individually, and
beyond which the serviceability of the circuit may be impaired. Functional
operability is not necessarily implied. Exposure to absolute maximum rating
conditions for an extended period of time may affect device reliability.
2Typical thermal impedances for “Z” package: θJC = 11°C/W; θJA = 30°C/W.
II. 100% production tested at 25°C, and sample tested at
specified temperatures. AC testing done on sample basis.
III. Sample tested only.
IV. Parameter is guaranteed by design and characteriza-
tion testing.
V. Parameter is a typical value only.
VI. All devices are 100% production tested at 25°C; sample
tested at temperature extremes.
Model
AD10265AZ
AD10265/PCB
5962-9865901 HXA
ORDERING GUIDE
Temperature Range
–25°C to +85°C (Case)
+25°C
–25°C to +125°C (Case)
Package Description
68-Lead Ceramic Leaded Chip Carrier
Evaluation Board with AD10265AZ
68-Lead Ceramic Leaded Chip Carrier
Package Option
ES-68C
ES-68C
5962R0151901 TXA
–25°C to +125°C (Case)
68-Lead Ceramic Leaded Chip Carrier
ES-68C
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection.
Although the AD10265 features proprietary ESD protection circuitry, permanent damage may
occur on devices subjected to high-energy electrostatic discharges. Therefore, proper ESD
precautions are recommended to avoid performance degradation or loss of functionality.
WARNING!
ESD SENSITIVE DEVICE
–4–
REV. A

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]