SST25PF080B
CE#
MODE 3
SCK MODE 0
0 1 23456 78
15 16
23 24 31
SI
D8
ADDR ADDR ADDR
MSB
MSB
SO
HIGH IMPEDANCE
25137 63KBlkEr.0
FIGURE 4-12:
64-KBYTE BLOCK-ERASE SEQUENCE
4.5.9 CHIP-ERASE
The Chip-Erase instruction clears all bits in the device
to FFH. A Chip-Erase instruction will be ignored if any
of the memory area is protected. Prior to any Write oper-
ation, the Write-Enable (WREN) instruction must be exe-
cuted. CE# must remain active low for the duration of
the Chip-Erase instruction sequence. The Chip-Erase
instruction is initiated by executing an 8-bit command,
60H or C7H. CE# must be driven high before the instruction
is executed. The user may poll the Busy bit in the software
status register or wait TCE for the completion of the
internal self-timed Chip-Erase cycle. See Figure 4-13
for the Chip-Erase sequence.
CE#
MODE 3
SCK MODE 0
0 1 23456 7
FIGURE 4-13:
SI
60 or C7
MSB
SO
HIGH IMPEDANCE
25137 ChEr.0
CHIP-ERASE SEQUENCE
4.6 Read Security ID
To execute a Read SID operation, the host drives CE#
low, sends the Read Security ID command cycle (88H),
one address cycle, and then one dummy cycle. Each
cycle is eight clock periods long, most significant bit
first.
After the dummy cycle, the device outputs data on the
falling edge of the SCK signal starting from the speci-
fied address location. The data output stream is contin-
uous through all SID addresses until terminated by a
low-to-high transition on CE#. The internal address
pointer automatically increments until the last SID
address is reached, then outputs 00H until CE# goes
high.
4.7 Lockout Security ID
The Lockout SID instruction prevents any future
changes to the Security ID. To execute a Lockout SID,
the host drives CE# low, sends the Lockout SID com-
mand cycle (85H), then drives CE# high. Each cycle is
eight clocks long, most significant bit first. Poll the
BUSY bit in the software status register, or wait TPSID,
for the completion of the Lockout SID operation.
2012 Microchip Technology Inc.