WS
79L12
equivalent schematic
COMMON
OUTPUT
INPUT
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Input voltage: 79L12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -35V
Operating free-air, case, or virtual junction temperature. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .150 °C
Lead temperature 1.6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 150°C
recommended operating conditions
79L12
Input voltage, VI
Output current, IO
Operating virtual junction temperature, TJ
MIN MAX UNIT
-14.5 -27 V
100 mA
0 70 °C
3-2