DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

ADUM6400 查看數據表(PDF) - Analog Devices

零件编号
产品描述 (功能)
生产厂家
ADUM6400 Datasheet PDF : 28 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Data Sheet
ADuM6400/ADuM6401/ADuM6402/ADuM6403/ADuM6404
REGULATORY INFORMATION
The ADuM6400/ADuM6401/ADuM6402/ADuM6403/ADuM6404 are approved by the organizations listed in Table 15. Refer to Table 20
and the Insulation Lifetime section for more information about the recommended maximum working voltages for specific cross-insulation
waveforms and insulation levels.
Table 15.
UL 1
Recognized under UL 1577 component
recognition program
Single protection, 5000 V rms isolation
voltage
File E214100
CSA (Pending)
Approved under CSA Component Acceptance Notice #5A
Basic insulation per CSA 60950-1-07 and IEC 60950-1,
600 V rms (848 V peak) maximum working voltage
RW-16 package:
Reinforced insulation per CSA 60950-1-07 and IEC 60950-1,
380 V rms (537 V peak) maximum working voltage
Reinforced insulation per IEC 60601-1, 125 V rms (176 V peak)
maximum working voltage
RI-16-1 package:
Reinforced insulation per CSA 60950-1-07 and IEC 60950-1,
400 V rms (565 V peak) maximum working voltage
Reinforced insulation per IEC 60601-1, 250 V rms (353 V peak)
maximum working voltage
File 205078
VDE
RW-16 package:2
Certified according to IEC 60747-5-2
(VDE 0884 Part 2):2003-01 (pending)
Basic insulation, 846 V peak
RI-16-1 package:3
Certified according to DIN V VDE V
0884-10 (VDE V 0884-10):2006-12
Reinforced insulation, 846 V peak
File 2471900-4880-0001
1 In accordance with UL 1577, each ADuM6400/ADuM6401/ADuM6402/ADuM6403/ADuM6404 is proof-tested by applying an insulation test voltage ≥ 6000 V rms for
1 sec (current leakage detection limit = 20 μA).
2 In accordance with IEC 60747-5-2 (VDE 0884 Part 2):2003-01, each ADuM6400/ADuM6401/ADuM6402/ADuM6403/ADuM6404 in the RW-16 package is proof-tested
by applying an insulation test voltage ≥ 1590 V peak for 1 sec (partial discharge detection limit = 5 pC). The asterisk (*) marking branded on the component designates
IEC 60747-5-2 (VDE 0884 Part 2):2003-01 approval.
3 In accordance with DIN V VDE V 0884-10 (VDE V 0884-10):2006-12, each ADuM6400/ADuM6401/ADuM6402/ADuM6403/ADuM6404 in the RI-16-1 package is proof-tested
by applying an insulation test voltage ≥ 1590 V peak for 1 sec (partial discharge detection limit = 5 pC). The asterisk (*) marking branded on the component designates
DIN V VDE V 0884-10 (VDE V 0884-10):2006-12 approval.
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 16.
Parameter
Rated Dielectric Insulation Voltage
Minimum External Air Gap (Clearance)
Symbol
L(I01)
Value
5000
8.0
Unit
V rms
mm
Minimum External Tracking (Creepage)
L(I02)
RW-16 Package
RI-16-1 Package
Minimum Internal Distance (Internal Clearance)
Tracking Resistance (Comparative Tracking Index) CTI
Material Group
7.6
mm
8.3
mm
0.017 min mm
>175
V
IIIa
Test Conditions/Comments
1-minute duration
Measured from input terminals to output terminals,
shortest distance through air
Measured from input terminals to output terminals,
shortest distance path along body
Distance through insulation
DIN IEC 112/VDE 0303, Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
Rev. A | Page 9 of 28