DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

DS1620 查看數據表(PDF) - Maxim Integrated

零件编号
产品描述 (功能)
生产厂家
DS1620
MaximIC
Maxim Integrated MaximIC
DS1620 Datasheet PDF : 12 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
DS1620
Write TL [02h]
This command writes to the TL (LOW TEMPERATURE) register. After issuing this command the next
nine clock cycles clock in the 9–bit temperature limit which will set the threshold for operation of the
TLOW output.
Read TH [A1h]
This command reads the value of the TH (HIGH TEMPERATURE) register. After issuing this command
the next nine clock cycles clock out the 9–bit temperature limit which sets the threshold for operation of
the THIGH output.
Read TL [A2h]
This command reads the value of the TL (LOW TEMPERATURE) register. After issuing this command
the next nine clock cycles clock out the 9–bit temperature limit which sets the threshold for operation of
the TLOW output.
Read Counter [A0h]
This command reads the value of the counter byte. The next nine clock cycles will output the contents of
this register.
Read Slope [A9h]
This command reads the value of the slope counter byte from the DS1620. The next nine clock cycles
will output the contents of this register.
Start Convert T [EEh]
This command begins a temperature conversion. No further data is required. In one–shot mode the
temperature conversion will be performed and then the DS1620 will remain idle. In continuous mode this
command will initiate continuous conversions.
Stop Convert T [22h]
This command stops temperature conversion. No further data is required. This command may be used to
halt a DS1620 in continuous conversion mode. After issuing this command the current temperature
measurement will be completed and then the DS1620 will remain idle until a Start Convert T is issued to
resume continuous operation.
Write Config [0Ch]
This command writes to the configuration register. After issuing this command the next eight clock cycles
clock in the value of the configuration register.
Read Config [ACh]
This command reads the value in the configuration register. After issuing this command the next eight
clock cycles output the value of the configuration register.
7 of 12

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]