FMA219
X-BAND LNA MMIC
ABSOLUTE MAXIMUM RATINGS1
Parameter
Symbol
Test Conditions
Min Max Units
Supply Voltage
Supply Current
VDD
For any operating current
IDD
For VDD < 5V
6
V
100
mA
RF Input Power
PIN
For standard bias conditions
-5
dBm
Storage Temperature
TSTG
Non-Operating Storage
-40
150
ºC
Total Power Dissipation
Gain Compression
Simultaneous Combination of Limits2
1TAmbient = 22°C unless otherwise noted
PTOT
Comp.
See De-Rating Note below
Under any bias conditions
600 mW
5
dB
2 or more Max. Limits
80
%
2Users should avoid exceeding 80% of 2 or more Limits simultaneously
Notes:
Operating conditions that exceed the Absolute Maximum Ratings will result in permanent damage to the device.
Total Power Dissipation defined as: PTOT (PDC + PIN) – POUT, where:
PDC: DC Bias Power
PIN: RF Input Power
POUT: RF Output Power
Total Power Dissipation to be de-rated as follows above 22°C:
PTOT= 0.6 - (0.004W/°C) x TCARRIER
where TCARRIER = carrier or heatsink temperature above 22°C
(coefficient of de-rating formula is the Thermal Conductivity)
Example: For a 55°C carrier temperature: PTOT = 0.6 - (0.004 x (55 – 22)) = 0.47W
For optimum heatsinking eutectic die attach is recommended; conductive epoxy die attach is acceptable with
some degradation in thermal de-rating performance (PTOT = 550mW)
Note on Thermal Resistivity: The nominal value of 250°C/W is stated for the input stage, which will reach
temperature limits before the output stage. The aggregate MMIC thermal resistivity is approximately 175°C/W.
HANDLING PRECAUTIONS
To avoid damage to the devices care should be exercised during handling. Proper Electrostatic
Discharge (ESD) precautions should be observed at all stages of storage, handling, assembly, and
testing. These devices should be treated as Class 1A per ESD-STM5.1-1998, Human Body Model.
Further information on ESD control measures can be found in MIL-STD-1686 and MIL-HDBK-263.
APPLICATIONS NOTES & DESIGN DATA
Applications Notes are available from your local Filtronic Sales Representative or directly from the
factory.
Phone: +1 408 850-5790
Fax: +1 408 850-5766
http://www.filtronic.co.uk/semis
Revised: 11/22/04
Email: sales@filcsi.com

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]