L9468
Figure 5. Setpoint Voltage vs. Tcase Temperature
VS
(V)
15.8
15.6
15.4
15.2
15.0
14.8
14.6
14.4
14.2
15.9
15.45
15
15.05
14.8
14.55
14.0
13.8
13.6
13.4
13.2
13.0
-40 -20
0
20
40
D02AT506
14.35
14.1
13.85
14
13.65
13.35
60
80 100 120 Tcase(˚C)
Table 6. Diagnostic (Tcase -35°C to +150°C unless otherwise specified)
Symbol
Parameter
Test Condition
Min. Typ.
Max. Unit
VFSO Failsafe Output Voltage
Voltage measured at VGO
20
20.48
21
V
VFSL Switch sensing from S to VGO "S" Voltage falling into Fail Soft 4
4
4.2
V
VFSH Switch sensing from VGO to S "S" Voltage rising out of Fail Soft
7.6
8
V
IS
Sink current @ "S" pin
VS = 14 V
1
1.75
2.5
mA
VUV Undervoltage
grpm > 3100 ± 15%
10.95 11.35
11.6
V
VOV Overvoltage
VS+1 VS+1.25 VS+1.55 V
VLSAT Lamp saturation voltage
IL = 0.5A
1.33
1.4
V
VLSAT Lamp on Voltage 5
IL < 0.5A,VGO=open, Tcase =
25°C
3.8
5
V
TDELAY Fault Indication Delay Time
0.935 1.1
1.265
s
Notes:
4. When Fail Soft operation is detected, regulation sensing will switch from the "S" terminal to the VGO terminal.
5. This condition can happen when the connection between the battery and VGO or the output terminal of the generator is broken.
In this case the delay of 1.1 seconds is not required.