M54124L
Absolute Maximum Ratings
Symbol
Is
Quantity
Power supply voltage
Conditions
(Unless otherwise noted, Ta = –20 to 80°C)
Rated value
Unit
8
mA
IS(SG)
IIN
IIG
Power supply surge current
Input current
Input pin current
(Note 1)
Across IN-VR (Note 2)
Across VR-GND, IN-GND
12
mA
–250 to +250
mA
30
mA
VOD
OD applied voltage
When an external voltage is applied 6
V
IMA
MA input voltage
When an external voltage is applied 4
mA
VOS
OS applied voltage
When an external voltage is applied 6
V
Pd
Power consumption
200
mW
Topr
Operating temperature
–20 to 80
°C
Tstg
Storage temperature
–55 to 125
°C
Remarks: When not specified, voltages are expressed taking the circuit GND pin level to be 0 V, and currents are
expressed taking the direction of flow into the circuit to be positive (no sign given), and the direction flowing
out to be negative (prepended with "-"). Rated values, standard values, and other maximum and minimum
values are given as absolute values.
Note 1: The IS(SG) current waveform is as indicated on the right; there is one shot or less in one minute.