MH8S72BAFD -7, -8 MITSUBISHI LSIs
P rSepl iemci.n a r y 603,979,776-BIT ( 8,388,608-WORD BY 72-BIT ) Synchronous DYNAMIC RAM
BASIC FUNCTIONS
The MH8S72BAFD provides basic functions,bank(row)activate,burst read / write,
bank(row)precharge,and auto / self refresh.
Each command is defined by control signals of /RAS,/CAS and /WE at CK rising edge. In
addition to 3 signals,/S,CKE and A10 are used as chip select,refresh option,and precharge
option,respectively.
To know the detailed definition of commands please see the command truth table.
CK
/S
/RAS
/CAS
/WE
CKE
A10
Chip Select : L=select, H=deselect
Command
Command
Command
define basic commands
Refresh Option @refresh command
Precharge Option @precharge or read/write command
Activate(ACT) [/RAS =L, /CAS = /WE =H]
ACT command activates a row in an idle bank indicated by BA.
Read(READ) [/RAS =H,/CAS =L, /WE =H]
READ command starts burst read from the active bank indicated by BA.First output
data appears after /CAS latency. When A10 =H at this command,the bank is
deactivated after the burst read(auto-precharge,READA).
Write(WRITE) [/RAS =H, /CAS = /WE =L]
WRITE command starts burst write to the active bank indicated by BA. Total data
length to be written is set by burst length. When A10 =H at this command, the bank is
deactivated after the burst write(auto-precharge,WRITEA).
Precharge(PRE) [/RAS =L, /CAS =H,/WE =L]
PRE command deactivates the active bank indicated by BA. This command also
terminates burst read / write operation. When A10 =H at this command, both banks are
deactivated(precharge all, PREA).
Auto-Refresh(REFA) [/RAS =/CAS =L, /WE =CKE =H]
PEFA command starts auto-refresh cycle. Refresh address including bank address are
generated internally. After this command, the banks are precharged automatically.