DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MLD1N06CL(2017) 查看數據表(PDF) - ON Semiconductor

零件编号
产品描述 (功能)
生产厂家
MLD1N06CL Datasheet PDF : 8 Pages
1 2 3 4 5 6 7 8
MLD1N06CL
FORWARD BIASED SAFE OPERATING AREA
The FBSOA curves define the maximum draintosource
voltage and drain current that a device can safely handle
when it is forward biased, or when it is on, or being turned
on. Because these curves include the limitations of
simultaneous high voltage and high current, up to the rating
of the device, they are especially useful to designers of linear
systems. The curves are based on a case temperature of 25°C
and a maximum junction temperature of 150°C. Limitations
for repetitive pulses at various case temperatures can be
determined by using the thermal response curves.
ON Semiconductor Application Note, AN569, “Transient
Thermal Resistance General Data and Its Use” provides
detailed instructions.
MAXIMUM DC VOLTAGE CONSIDERATIONS
The maximum draintosource voltage that can be
continuously applied across the MLD1N06CL when it is in
current limit is a function of the power that must be
dissipated. This power is determined by the maximum
current limit at maximum rated operating temperature
10
VGS = 10 V
SINGLE PULSE
TC = 25°C
(1.8 A at 150°C) and not the RDS(on). The maximum voltage
can be calculated by the following equation:
Vsupply =
(150 TA)
ID(lim) (RqJC + RqCA)
where the value of RqCA is determined by the heatsink that
is being used in the application.
DUTY CYCLE OPERATION
When operating in the duty cycle mode, the maximum
drain voltage can be increased. The maximum operating
temperature is related to the duty cycle (DC) by the
following equation:
TC = (VDS x ID x DC x RqCA) + TA
The maximum value of VDS applied when operating in a
duty cycle mode can be approximated by:
VDS =
150 TC
ID(lim) x DC x RqJC
10 ms
1.0
100 ms
1 ms
10 ms
0.1
0.1
RDS(on) LIMIT
THERMAL LIMIT
PACKAGE LIMIT
dc
1.0
10
100
VDS, DRAIN-TO-SOURCE VOLTAGE (VOLTS)
Figure 8. Maximum Rated Forward Bias
Safe Operating Area (MLD1N06CL)
1.0
D = 0.5
0.2
0.1
0.1 0.05
0.02
0.01
SINGLE PULSE
0.01
1.0E - 05
1.0E - 04
P(pk)
t1
t2
DUTY CYCLE, D = t1/t2
RqJC(t) = r(t) RqJC
D CURVES APPLY FOR POWER
PULSE TRAIN SHOWN
READ TIME AT t1
TJ(pk) - TC = P(pk) RqJC(t)
1.0E - 03
1.0E - 02
1.0E - 01
t, TIME (s)
Figure 9. Thermal Response (MLD1N06CL)
1.0E+00
1.0E+01
www.onsemi.com
5

Share Link: 