MTD6N20E
SAFE OPERATING AREA
100
VGS = 20 V
SINGLE PULSE
TC = 25°C
10
10 ms
100 ms
1.0
1 ms
0.1
0.1
RDS(on) LIMIT
THERMAL LIMIT
PACKAGE LIMIT
10 ms
dc
1.0
10
100
1000
VDS, DRAIN-TO-SOURCE VOLTAGE (VOLTS)
Figure 11. Maximum Rated Forward Biased
Safe Operating Area
60
ID = 6 A
50
40
30
20
10
0
25
50
75
100
125
150
TJ, STARTING JUNCTION TEMPERATURE (°C)
Figure 12. Maximum Avalanche Energy versus
Starting Junction Temperature
1
D = 0.5
0.2
0.1
0.1 0.05
0.02
0.01
SINGLE PULSE
0.01
1.0E-05
1.0E-04
P(pk)
t1
t2
DUTY CYCLE, D = t1/t2
1.0E-03
1.0E-02
t, TIME (s)
1.0E-01
Figure 13. Thermal Response
RqJC(t) = r(t) RqJC
D CURVES APPLY FOR POWER
PULSE TRAIN SHOWN
READ TIME AT t1
TJ(pk) - TC = P(pk) RqJC(t)
1.0E+00
1.0E+01
IS
tp
di/dt
trr
ta
tb
0.25 IS
IS
TIME
Figure 14. Diode Reverse Recovery Waveform
http://onsemi.com
6