Micrel
DC ELECTRICAL CHARACTERISTICS
VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND
TA = 0°C
TA = +25°C
TA = +85°C
Symbol
Parameter
Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Unit
VCUT
IIH
Cut-off Output Voltage
Input HIGH Current
RXEN
All Other Inputs
–2.10 — –2.03 –2.10 — –2.03 –2.10 — –2.03 V
µA
— — 225 — — 225 — — 225
— — 150 — — 150 — — 150
IEE
Power Supply Current
mA
10E — 125 150 — 125 150 — 125 150
100E — 125 150 — 125 150 — 144 173
NOTE:
1. Measured with VTT = –2.10V.
SY10E336
SY100E336
Condition
1
—
—
AC ELECTRICAL CHARACTERISTICS
VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND
Symbol
Parameter
TA = 0°C
TA = +25°C
TA = +85°C
Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Unit
tPLH
Propagation Delay to Output
ps
tPHL
CLK to Q
500 700 1000 500 700 1000 500 700 1000
CLK to BUS
825 1250 1800 825 1250 1800 825 1250 1800
tS
Set-up Time
BUS, RXEN
BUSEN
A, B Data
TEN
ps
150 –150 — 150 –150 — 150 –150 —
100 –200 — 100 –200 — 100 –200 —
300 –50 — 300 –50 — 300 –50 —
450 150 — 450 150 — 450 150 —
tH
Hold Time
BUS, RXEN
BUSEN
A, B Data
TEN
ps
450 150 — 450 150 — 450 150 —
500 200 — 500 200 — 500 200 —
350 50 — 350 50 — 350 50 —
200 –150 — 200 –150 — 200 –150 —
tPW
Minimum Pulse Width, CLK 400 — — 400 — — 400 — — ps
tr
Rise/Fall Time
ps
tf
20% to 80% (Qn)
300 450 700 300 450 700 300 450 700
20% to 80% (BUSn Rise)
500 800 1000 500 800 1000 500 800 1000
20% to 80% (BUSn Fall)
300 500 800 300 500 800 300 500 800
Condition
—
—
—
—
—
PRODUCT ORDERING CODE
Ordering
Code
SY10E336JC
SY10E336JCTR
SY100E336JC
SY100E336JCTR
Package
Type
J28-1
J28-1
J28-1
J28-1
Operating
Range
Commercial
Commercial
Commercial
Commercial
3