1 2 3 4 5 6 7 8 9 10 Next Last
Operation
Functions
Operation Mode
Relationship between G9SX-LM outputs (safety instantaneous
outputs and safety speed detection outputs) and inputs (safety input,
enabling input, rotation detection input) differs depends on mode
selector input status.
Normal operation mode (Mode selector input M1=ON, M2=OFF)
Safety instantaneous outputs and safety speed detection outputs
condition turn on depending on rotation detection input condition.
Safety input
ON
OFF
Enabling input
-
-
-
-
Rotation detection
input
(low speed detection
frequency)
Over 2Hz
Equal to
or less
than 2Hz
Over 2Hz
Equal to
or less
than 2Hz
Safety
instantaneous
ON
output
OFF
Safety speed
detection output
OFF
ON
OFF
ON
Maintenance mode (Mode selector input M1=OFF, M2=ON)
Safety instantaneous outputs changes depending on enabling input
and rotation detection input condition. Safety speed detection outputs
turn on depending on rotation detection input condition.
Safety input
-
-
-
-
Enabling input
ON
OFF
Rotation detection
input
(low speed detection
frequency)
Equal to
or less
than the
preset
value
Over the
preset
value
Equal to
or less
than the
preset
value
Over the
preset
value
Safety
instantaneous
output
ON
OFF
OFF
Safety speed
detection output
ON
OFF
ON
OFF
Note: 1. When the logical AND preset switch is set to AND (enabled),
the logical AND connection input must be ON for the safety
instantaneous output to be turned ON.
2. Safety instantaneous outputs turn on when the feedback
reset inputs condition satisfies its condition and above
stated one. Reset mode (auto reset or manual reset) shall
be selected depending on the application.
Logical AND Connection
The logical AND connection means that the Basic Unit (or Advanced
Unit) outputs a safety signal "a" to an Advanced Unit, and the
Advanced Unit calculates the logical multiplication (AND) of the safety
signal "a" and safety signal "b." The safety output of an Advanced Unit
with the logical AND connection shown in the following diagram is "a"
AND "b".
a
Unit A
b
Unit B
a
a (AND) b
Note: For details on Logical AND Connection, see "G9SX/G9SX-GS
Datasheet".
G9SX-LM
Low-speed Detection Function
Converts the pulse signals from two proximity sensors that monitor
the rotation status of hazards to frequency to control the safety speed
detection outputs.
• The diagram below shows the relationship between the Low-speed
detection frequency and Safety speed detection outputs. The
frequency (F) has a tolerance of - 10%.
• This accuracy tolerance does not include any characteristics of
proximity sensors.
(Hz)
F
F-10 %
Safety speed ON
Detection output OFF
F = Frequency monitoring threshold
Normal operating mode: 2Hz (fixed)
Maintenance mode:
Low-speed detection settings value
(Time)
Use the following OMRON E2E series three-wire DC sensors (PNP).
E2E-X1R5F1
E2E-X2F1
E2E-X5F1
E2E-X2MF1
E2E-X5MF1
E2E-X10MF1
Note: 1. To monitor the rotation status of hazards, install a cogwheel
for proximity sensors linked to hazards as follows. For
design of cogwheel and installation of proximity sensors,
see page 13 "Shape of Cogwheel and Setting of Proximity
Sensors".
S2
S1
2. If G9SX-LM@ is operated without proximity sensors being
connected, G9SX-LM@ will detect it as an error.
3. If both sensors do not detect the cogwheel, G9SX-LM@ will
detect it as an error.
Auxiliary outputs
Auxiliary outputs X1 to X4 can be used to notify outputs, error status,
and operation mode.
Terminal
name
Signal name
Output ON requirement
Safety
X1
instantaneou X1 is turned ON when Safety
s outputs
instantaneous output is ON.
monitor
X2
Error monitor
X2 is turned ON when an error LED
indicator is lit or blinking.
Safety speed
X3
detection
outputs
X3 is turned ON when Safety speed
detection output is ON.
monitor
X4
Operation
mode
monitor
X4 is turned ON when in the
Maintenance mode.