AM1 (NZ) Basic Switches
Oil tight types
Hinge lever
CAD Data
Plunger seal
26.1
R63.5
20.1±0.5
AM1511F (Solder terminal)
AM1711F (Screw terminal)
Hinge short roller lever
CAD Data
Plunger seal
26.1
20.1±0.5 16.9±0.8
R26.7
AM1514F (Solder terminal)
AM1714F (Screw terminal)
Lever: Stainless steel
4.8
FP
OP
Roller 9.5 dia.×4:
Plastic
OP FP
To Be Discontinued
Last time buy: September 30, 2018
Operating Force OF, max.
0.69 N
Release Force RF, min.
0.14 N
Pretravel PT, max.
Movement Differential
MD, max.
Overtravel OT, min.
10 mm
1.5 mm
5.6 mm
Operating Position OP
19.1±0.7 mm
Operating Force OF, max.
1.67 N
Release Force RF, min.
0.42 N
Pretravel PT, max.
Movement Differential
MD, max.
Overtravel OT, min.
Operating Position OP
4.5 mm
0.7 mm
2.4 mm
30.2±0.4 mm
Hinge roller lever
CAD Data
The photograph is a case of a screw terminal. The dimension is an intersection except a terminal section.
Please refer to “TERMINAL STYLE” for the shape and size of terminal section.
Plunger seal
26.1
R48.3
20.1±0.5 16.9±0.8
AM1513F (Solder terminal)
AM1713F (Screw terminal)
Roller 9.5 dia.×4:
Plastic
FP
OP
Operating Force OF, max.
0.98 N
Release Force RF, min.
0.20 N
Pretravel PT, max.
Movement Differential
MD, max.
Overtravel OT, min.
7.5 mm
1.3 mm
3.6 mm
Operating Position OP
30.2±0.7 mm
CAUTIONS FOR USE
Regarding fastening of switch body
In fastening the switch body, use M4 mounting screws to attach
switches with the torque 1.5 N·m or less.
Soldering operations
Perform soldering in less than 3 seconds with maximum 350°C
iron. Care should be taken not to apply force to the terminals
during soldering. We recommend a soldering iron with
temperature adjustment in order to prevent poor quality
soldering.
Please consult us if you intend to use a soldering iron of 60 W or
higher.
Panel mount type
1) When mounting the panel, tighten the hex nut for actuator to
less than 4.0 N·m.
2) Mounting hole dimensions are as shown below.
Mounting hole dimensions
Panel mount
plunger
12.5 dia.
Panel mount roller
plunger
12.5 dia.
5
13
Environment
Avoid using and storing these switches in a location where they
will be exposed to corrosive gases, silicon, or high dust levels, all
of which can have an adverse effect on the contacts.
–8–