HSP45116-DB
in turn drives the clock input of the HSP45116. The jumper
inserted between JA2 and SA2 allows the Input Header’s
CLK_IN pin to be driven by the buffer output. NOTE: The
jumper placement shown in Figure 5 is the standard
configuration..
1
FIGURE 5. JUMPER CONFIGURATION IF CLOCK IS SUP-
PLIED THROUGH J1 INPUT HEADER
1
FIGURE 6. JUMPER CONFIGURATION IF CLOCK IS SUP-
PLIED THROUGH J2 OUTPUT HEADER
The HSP45116-DB is shipped from the factory with the
default jumper configuration shown by the overlay of heavy
lines onto the signal map in Table 1. For the Control Panel
and Command Line Interface software to properly control
operation of the HSP45116, it is assumed that the
HSP45116 control inputs are jumpered as specified in the
default configuration. Also, the system test software,
NCOM_CHK, must be run using the default configuration.
Appendix A
Data File Structures
The Input/Output data files used by the HSP45116-DB
Control Panel and Command Line Interface software contain
complex data samples. The data files consist of a seven line
header followed by the data itself. The header section must
follow this format:
Line 1:
Comment #1
Line 2:
Comment #2
Line 3:
Comment #3
Line 4:
Comment #4
Line 5:
Comment #6
Line 7:
c1n
(Real Component) (Imaginary Component)
The ‘n’ on the 7th line of the header should be replaced by
the number of complex samples in the file. Following the
header, the complex samples are listed one per row with the
real part listed first followed by the complex part. The real
and imaginary components of the complex data sample are
represented as 16-bit two’s complement values. As a result,
the real and imaginary parts of the data sample are integer
values bounded by 32767 and -32768. The CMPRFILE
installed in the NCOM_CHK subdirectory is an example of
the input data file structure.