DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

HSDL-1000 查看數據表(PDF) - HP => Agilent Technologies

零件编号
产品描述 (功能)
生产厂家
HSDL-1000
HP
HP => Agilent Technologies HP
HSDL-1000 Datasheet PDF : 10 Pages
1 2 3 4 5 6 7 8 9 10
Electrical & Optical Specifications
Specifications hold over the Recommended Operating Conditions unless otherwise noted. Test Conditions represent worse case
values for the parameters under test. Unspecified test condition can be anywhere in their recommended operating range. All typicals
are at 25°C and 5V unless otherwise noted.
Parameter
Symbol Min. Typ. Max. Unit
Conditions Fig.
Receiver Data Logic Low[2] VOL (RXD)[2,3]
Output Voltage
Logic High
VOH (RXD) VCC -0.5
0.4
V IO = 0.3 mA
For In-Band
EI 3.6 µW/cm2;
θ ≤ 15°
V IO = -20 µA,
For In-Band
EI 0.3 µW/cm2
Effective
Detector Area
Transmitter
Logic Low
IEL
Radient
Intensity
Logic High
Intensity
IEH
Peak
λp
Wavelength
0.2
cm2
0.3 µW/SR VI 0.3 V
44
250 mW/SR ILEDA = 250 mA,
4, 6
VI = 2.5 V, θ ≤ 30°
40 mW/SR ILEDA = 250 mA,
VI = 2.5 V; θ > 60°
875
nm
6
Transmitter
Receiver
Transmitter
Data Input
Current
LED Anode On
State Voltage
LED Anode Off
State Leakage
Supply Current
TXD High
Spectral Line
Half Width
Viewing Angle
Logic Low
Logic High
VON (LEDA)
ILK (LEDA)
ICC1
∆λ1/2
θ
φ
IIL(TXD)
IIH(TXD)
35
nm
6
30
60
°
7
30
°
-1.0
1.0 µA Gnd VI 0.3 V
4.5
mA VI = 2.5 V
1
2.50
100
1.1
V ILEDA = 250 mA,
1, 3
Tj = 25°C
µA VLEDA = VCC = 5.5 V,
VI = 0.3V
mA VCC = 5.5,
11
VI (TXD) = VIH,
ILED = 250 mA,
EI = 0
Supply Current ICC2
RXD Low[2]
Receiver Peak λp
Sensitivity
Wavelength
13 mA VCC = 5.5,
1
VI (TXD) = VIL,
EI = 500 mW/cm2
880
nm
9
Notes:
1. EI – received in band light intensity present at detector surface.
2. Pulsed Response – Logic Low is a pulsed response. A receiver output low state VOL (RXD) is not indefinitely maintained but is instead a
pulsed response. The output low state is maintained for a duration dependent on the incident bit pattern and
incident intensity (EI).
3. The EI 3.6 µW/cm2 condition guarantees the IrDA minimum receiver sensitivity of 4.0 µW/cm2 while allowing for 10% light loss
through a cosmetic window placed in front of the HSDL-1000. (See the Rx TH+ section at the end of this data sheet for information
on receiver sensitivity over temperature, and in the presence of ambient light.)
4-38