Model
Number
HEC75-48S1P8
Input
Range
36 – 75 VDC
Output
Output Current
Line
Load
Voltage Min. load Full load Regulation Regulation
1.8 VDC
0mA
20 A
4 mV
6 mV
Input Current
No
load(3)
Full
load(2)
120mA
0.926 A
HEC75-48S2P5 36 – 75 VDC 2.5 VDC
0mA
20 A
5 mV
8 mV
90mA
1.255 A
HEC75-48S3P3 36 – 75 VDC 3.3 VDC
0mA
20 A
7 mV
10 mV
120mA
1.618 A
HEC75-48S05 36 – 75 VDC 5.0 VDC
0mA
15 A
10 mV
15 mV
130mA
1.838 A
HEC75-48S15 36 – 75 VDC 15 VDC
0mA
5A
30 mV
45 mV
160mA
1.860 A
Eff (4)
(%)
85
87
90
90
90
Model Number Input Range
HEC75-48D3305 36 – 75 VDC
Output Voltage
V1
V2
5 VDC
3.3 VDC
HEC75-48D3325 36 – 75 VDC 3.3 VDC 2.5 VDC
HEC75-48D0518 36 – 75 VDC
5 VDC
1.8 VDC
HEC75-48D3318 36 – 75 VDC 3.3 VDC 1.8 VDC
Output Current
I1
I2
15 A
15 A
15 A
15 A
15 A
15 A
15 A
15 A
Line
Regulation
10/7 mV
7/5 mV
10/4 mV
7/4 mV
Load
Regulation
15/10 mV
10/8 mV
15/6 mV
10/6 mV
Eff (4)
(%)
88
81
85
81
Note
1. BELLCORE TR-NWT-000332. Case 1: 50% Stress, Temperature at Tc=40ºC.
MIL-HDBK-217F Notice2 @Ta=25 ºC, Full load(Ground, Benign, controlled environment).
2. Maximum value at nominal input voltage and full load.
3. Typical value at nominal input voltage and no load.
4. Single:Typical value at nominal input voltage and full load.
Dual:Typical value at nominal input voltage and both outputs current are 7.5A.
5. Maximum output deviation is 10% inclusive of remote sense. If remote sense is not being used, the + sense should be connected to its corresponding
+OUTPUT and likewise the -sense should be connected to its corresponding –OUTPUT.
6. Measured with a 1μF M/C and a 10μF M/C(for dual outputs) or 1μF M/C and a 10μF T/C(for single outputs)
7. Dual output safety approvals pending.
8. The negative / positive logic and pin length are optional. The pin voltage is referenced to -Vin.
Single:Please see single output product options table.
Dual:Please see dual output product options table.
9. Heat sink is optional and P/N: 7G-0021A-F, 7G-0022A-F, 7G-0023A-F, 7G-0024A-F.
10. The HEC75 meets EN55022 class A and class B only with external components connected with the input pins of the converter.
11. An external input filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5.
The filter capacitor Power Mate suggest: Nippon chemi-con KY series, 220μF/100V, ESR 48mΩ.
12. BASEPLATE GROUNDING:Base-plate should be grounded at one of the four screw bolts prior to operation.
13. The converter is provided by basic insulation.
Page 2 of 4 Issued Date:2008/05/21