FE6A THRU FE6D
GLASS PASSIVATED FAST EFFICIENT RECTIFIER
Reverse Voltage - 50 to 200 Volts
Forward Current - 6.0 Amperes
*
TED
Case Style G4
TEN
PA
0.180 (4.6)
1.0 (25.4)
MIN.
0.115 (2.9)
DIA.
0.300 (7.6)
MAX.
0.042 (1.07)
0.038 (0.962)
DIA.
1.0 (25.4)
MIN.
Dimensions in inches and (millimeters)
*Brazed lead assembly is covered by Patent No. 3,930,306
FEATURES
High temperature metallurgically bonded construction
Glass passivated cavity-free junction
Superfast recovery time-for high efficiency
Low forward voltage, high current capability
Capable of meeting environmental standards
of MIL-S-19500
Hermetically sealed package
Low leakage current
High surge current capability
High temperature soldering guaranteed:
350°C/10 seconds, 0.375" (9.5mm) lead length,
5 lbs, (2.3kg) tension
MECHANICAL DATA
Case: Solid glass body
Terminals: Plated axial leads, solderable per MIL-STD-750,
Method 2026
Polarity: Color band denotes cathode end
Mounting Position: Any
Weight: 0.037 ounce, 1.04 grams
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
R. atings at 25°C ambient temperature unless otherwise specified.
SYMBOLS
FE6A
FE6B
FE6C
Maximum repetitive peak reverse voltage
Maximum RMS voltage
Maximum DC blocking voltage
Maximum average forward rectified current
0.375" (9.5mm) lead length at TL=55°C
Peak forward surge current
8.3ms single half sine-wave superimposed
on rated load (JEDEC Method)
VRRM
50
VRMS
35
VDC
50
I(AV)
IFSM
100
150
70
105
100
150
6.0
135.0
Maximum instantaneous forward voltage at 6.0A
Maximum DC reverse current
at rated DC blocking voltage
TA=25°C
TA=100°C
Maximum reverse recovery time (NOTE 1)
Typical junction capacitance (NOTE 2)
Typical thermal resistance (NOTE 3, 4)
Operating junction and storage temperature range
VF
IR
trr
CJ
RΘJA
RΘJL
TJ, TSTG
0.975
5.0
50.0
35.0
100.0
55.0
18.0
-65 to +175
NOTES:
(1) Reverse recovery test conditions: IF=0.5A, IR=1.0A, Irr=0.25A
(2) Measured at 1.0 MHZ and applied reverse voltage of 4.0 Volts
(3) Thermal resistance from junction to lead at 0.375" (9.5mm) lead length with both leads attached to heatsinks
(4) Thermal resistance from junction to ambient at 0.375" (9.5mm) lead length and mounted on P.C.B.
FE6D
200
140
200
UNITS
Volts
Volts
Volts
Amps
Amps
Volts
µA
ns
pF
°C/W
°C