DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

FKC05 查看數據表(PDF) - Power Mate Technology

零件编号
产品描述 (功能)
生产厂家
FKC05
P-DUKE
Power Mate Technology P-DUKE
FKC05 Datasheet PDF : 4 Pages
1 2 3 4
FKC05
FKC05W
GENERAL SPECIFICATIONS
Parameter
Isolation voltage
1 minute
Isolation resistance
Isolation capacitance
Switching frequency
Safety approvals
500VDC
Conditions
DIP type
Input to Output
Input (Output) to Case
SMD type
Input to Output
Input (Output) to Case
Case material
Base material
Potting material
Weight
MTBF
MIL-HDBK-217F
Min. Typ. Max. Unit
1600
1600
1600
VDC
1000
1
G
300
pF
270
300
330
kHz
UL60950-1
EN60950-1
IEC60950-1
Nickel-coated copper
Non-conductive black plastic
Epoxy (UL94 V-0)
18g (0.62oz)
5.831 x 106 hrs
ENVIRONMENTAL SPECIFICATIONS
Parameter
Operating ambient temperature(1)
Maximum case temperature
Storage temperature range
Thermal impedance
Thermal shock
Vibration
Relative humidity
Natural convection
Conditions
Standard
M1 Version
M2 Version
With derating
Without derating
With derating
Standard type
M2 Version
M1 Version
Min.
-25
-40
-40
-55
Typ.
20
Max. Unit
+85
+85
+85
100
100
105
+125
℃℃/W
MIL-STD-810F
MIL-STD-810F
5% to 95% RH
EMC SPECIFICATIONS
Parameter
EMI(2)
ESD
Radiated immunity
Fast transient (3)
Surge (3)
Conducted immunity
EN55022
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
Conditions
Air ± 8kV and Contact ± 6kV
10 V/m
± 2kV
± 1kV
10 Vr.m.s
Level
Class AClass B
Perf. Criteria A
Perf. Criteria A
Perf. Criteria B
Perf. Criteria B
Perf. Criteria A
Note:
1. It’s higher efficiency for M1 version. Therefore, it can be operated in a more extensive temperature range than standard and M2 version.
2. The standard modules meet EMI Class A or Class B with external components. For further information, please contact with P-DUKE.
3. An external input filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5.
The filter Power Mate suggests: Nippon chemi-con KY series, 220µF/100V.
CAUTION: This power module is not internally fused. An input line fuse must always be used.