DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

HP3-ML-DC110V 查看數據表(PDF) - Matsushita Electric Works

零件编号
产品描述 (功能)
生产厂家
HP3-ML-DC110V
Nais
Matsushita Electric Works Nais
HP3-ML-DC110V Datasheet PDF : 11 Pages
1 2 3 4 5 6 7 8 9 10
HP
HP4-SRS (with hold-down clip)
Optimum space-saving panel cut-out.
Can be mounted from either the front or
the rear of the panel.
Front surface-mounting
4.2±0.1 DIA. HOLE or
4 mm SCREW HOLE
.165±.004 DIA. HOLE
mm inch
HOLD-DOWN CLIP
5
.197
22
.866
5
.197
48±0.2
1.890
±.008
56
38
1.496
2.205
33
1.299
6.2
4.1
.244
.161
58
2.283
1.0 .039
6 .236
5.5
.217
13
.512
34
+1
–0
1.339
+.039
48±0.5
1.890
±.020
–0
48
+1
–0
+.039
–0
Rear surface-mounting
4.2±0.1 DIA. HOLE or
4 mm SCREW HOLE
.165±.004 DIA. HOLE
Dimension :
General tolerance
Max. 2mm .079 inch:
±0.2 ±.008
2 to 9mm .079 to .354 inch: ±0.5 ±.020
9 to 20mm .354 to .787 inch: ±1.0 ±.039
Min. 20mm .787 inch:
±1.5 ±.059
HP4-SFD (with hold-down clip)
Front wiring in restricted space.
Two HP2 relays can be mounted in one socket.
10±0.2
.394±.008
25±0.1
.984±.004
10±0.2
.394±.008
HOLD DOWN CLIP
HP4 RELAY
5.8±0.2
.228±.008
7.5±0.2
.295±.008
9.5±0.2
.374±.008
0.6±0.15
.024±.006
58±1
2.283±.039
69±1
2.717±.039 36±1
1.417±.039
39
+1
–0
1.535
+.039
48±0.5
1.890
±.020
–0
58
+1
–0
2.284
+.039
–0
23.8±0.6
.937±.024
80±1
3.150±.039
35.4±0.5
1.394±.020
15±0.2
.591±.008
15±0.2
.591±.008
53±0.6
2.087±.024
6±0.3
.236±.012
4.1±0.3
.161±.012
Dimension :
General tolerance
Max. 2mm .079 inch:
±0.2 ±.008
2 to 9mm .079 to .354 inch: ±0.5 ±.020
9 to 20mm .354 to .787 inch: ±1.0 ±.039
Min. 20mm .787 inch:
±1.5 ±.059
10±0.6
.394±.024
33.8±0.6
1.331±.024
37.9±0.6
Max. 85 3.346 1.492±.024
Max. 89 3.504
Installation screw
block
(installation screw,
hexagonal nut,
spring washer)
ACCESSORIES for HP2 and HP4 types
HP Bracket (with 2 screws, 2 washers)
The HP Bracket is used for mounting HP2
relays and HP4 relays directly to the pan-
el. It facilitates soldering or quick connec-
tions with Faston 205 tab 0.8 mm .031
inch.
Notes:
1. This bracket is unavailable for UL, CSA
and VDE applications.
2. When using the special bracket, it is
recommended to use the screws and
washers called out in the chart in the next
page in order to eliminate any possible
damage to the relay coil.
Mounting methods
(a) Remove the M3 × 7 screw (red col-
ored) fixed to the relay, and place the
bracket on the relay with the attaching M3
× 7 screw (blue colored) and the spring
washer.
Keying tab.
53±3
2.087±.118
13 .512
52±3
2.047±.118
14
.551
HP RELAY
HP SOCKET
4 mm SCREW
SPRING WASHER
PANEL
HOLD-DOWN CLIP
HP RELAY
HP SOCKET
4 mm SCREW
SPRING WASHER
PANEL
Mounting dimensions
53±0.2
2.087±.008
12
.472
2-M4 .157 SCREW HOLE or
4.2±0.1 .165±.004 DIA. HOLE
53±0.2
2.087±.008
69±0.5
2.717±.020
80
3.150
61
2.402
4 .157
61
2.402
Panel hole dimensions
for side-by-side installation
Note: Hold down clip and installation screw block are
included in package.
(b) Use the additional M3 × 7 screw and
washer for attaching the bracket to the
panel.
For the HP4 type relay
8 two brackets are used
.315
14
.551
90°±3°
23
.906
4
.158
14
.55120
.787
3.5 DIA. HOLE
.138 DIA. HOLE
2 .079
8.5
.335
1
.039
3 DIA. HOLE
.118 DIA. HOLE
420

Share Link: 