DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

HP3-ML-DC110V 查看數據表(PDF) - Matsushita Electric Works

零件编号
产品描述 (功能)
生产厂家
HP3-ML-DC110V
Nais
Matsushita Electric Works Nais
HP3-ML-DC110V Datasheet PDF : 11 Pages
1 2 3 4 5 6 7 8 9 10
AC TYPE (50/60 Hz) at 60 Hz, 20°C 68°F
Type
Part No.
Nominal coil
voltage, V AC
HP2-AC6V
6
HP2-AC12V
12
HP2-AC24V
24
2 Form C HP2-AC48V
48
HP2-AC115V
115
HP2-AC220V
220
HP2-AC240V
240
HP3-AC6V
6
HP3-AC12V
12
HP3-AC24V
24
3 Form C HP3-AC48V
48
HP3-AC115V
115
HP3-AC220V
220
HP3-AC240V
240
HP4-AC6V
6
HP4-AC12V
12
HP4-AC24V
24
4 Form C HP4-AC48V
48
HP4-AC115V
115
HP4-AC220V
220
HP4-AC240V
240
NOTES
1. The range of coil current for AC relays
is ±15% (60 Hz). For DC relays it is
±10% at 20°C, 68°F.
2. The HP relay will operate in a range
from 80% to 110% of the nominal coil
voltage. It is, however, recommended
that the relay be used in the range of
85% to 110% of the nominal coil volt-
age, with the temporary voltage varia-
tion taken into consideration.
3. When the operating voltage of AC re-
Pick-up
voltage,
V AC (max.)
4.8
9.6
19.2
38.4
92
176
192
4.8
9.6
19.2
38.4
92
176
192
4.8
9.6
19.2
38.4
92
176
192
Drop-out
voltage,
V AC (min.)
1.8
3.6
7.2
14.4
34.5
66
72
1.8
3.6
7.2
14.4
34.5
66
72
1.8
3.6
7.2
14.4
34.5
66
72
Max.
allowable
voltage, V AC
6.6
13.2
26.4
52.8
126.5
242
264
6.6
13.2
26.4
52.8
126.5
242
264
6.6
13.2
26.4
52.8
126.5
242
264
lays drops below 80% of the nominal
coil voltage, the relay will generate a
considerable amount of heat which is
not recommended for maximum effi-
ciency.
4. The coil resistance of DC types is the
measured value of the coil at a temper-
ature of 20°C 68°F. If the coil tempera-
ture changes by ±1°C, the measured
value of the coil resistance should be
increased or decreased by 0.4%.
HP
Inductance,
H
0.049
0.190
0.776
3.106
15.83
57.90
66.26
0.030
0.119
0.475
1.899
10.36
39.32
44.05
0.019
0.077
0.309
1.292
6.953
26.57
29.75
Nominal coil
current, mA
310
160
78
39
18
9.5
9.0
520
260
130
65
28.5
14.2
13.9
800
400
200
95
42
21
20.5
Nominal
operating
power, VA
1.9
1.9
1.9
1.9
2.1
2.1
2.2
3.1
3.1
3.1
3.1
3.3
3.1
3.3
4.8
4.8
4.8
4.6
4.8
4.6
4.9
5. For applications from 220 V to 240 V
DC, connect a resistor in series with
the relay coil. See chart for resistor val-
ues.
Voltage 2 Form C 3 Form C 4 Form C
220 V DC
7.3 k
(5 W)
7.45 k
(5 W)
7 k
(5 W)
240 V DC
8.7 k
(5 W)
8.8 k
(5 W)
8.3 k
(5 W)
2. Standard plug-in terminal type (with lamp wired)
DC TYPES at 20°C 68°F
Type
Part No.
Nominal coil Pick-up
Drop-out
voltage,
voltage,
voltage,
V DC V DC (max.) V DC (min.)
HP2-L-DC6V
6
4.8
0.9
HP2-L-DC12V
12
9.6
1.8
LED
2 Form C
HP2-L-DC24V
24
19.2
3.6
HP2-L-DC48V
48
38.4
7.2
Neon lamp HP2-L-DC110V
110
88
16.5
HP3-L-DC6V
6
4.8
0.9
HP3-L-DC12V
12
9.6
1.8
LED
3 Form C
HP3-L-DC24V
24
19.2
3.6
HP3-L-DC48V
48
38.4
7.2
Neon lamp HP3-L-DC110V
110
88
16.5
HP4-L-DC6V
6
4.8
0.9
HP4-L-DC12V
12
9.6
1.8
LED
4 Form C
HP4-L-DC24V
24
19.2
3.6
HP4-L-DC48V
48
38.4
7.2
Neon lamp HP4-L-DC110V
110
88
16.5
Max.
allowable
voltage,
V DC
6.6
13.2
26.4
52.8
121
6.6
13.2
26.4
52.8
121
6.6
13.2
26.4
52.8
121
Coil
Nominal coil
resistance, current,
(±10%)
mA
25
240
110
109
440
54.5
1,800
26.7
7,300
15.0
24
250
100
120
400
60
1,560
31
7,450
14.9
22
273
95
127
380
63
1,500
32
7,000
15.7
Nominal
operating
power,
W
1.5
1.3
1.3
1.3
1.7
1.5
1.4
1.4
1.5
1.6
1.6
1.5
1.5
1.5
1.7
413

Share Link: 