LT1780/LT1781
ELECTRICAL CHARACTERISTICS (Note 2)
PARAMETER
CONDITIONS
MIN TYP MAX
UNITS
Logic Input Current
Output Short-Circuit Current
Output Leakage Current
Data Rate
Slew Rate
Propagation Delay
Receiver
0.8V VIN 2.0V
VOUT = 0V
SHUTDOWN VOUT = ±30V (Note 4)
RL = 3k, CL = 2500pF
RL = 3k, CL = 1000pF
RL = 3k, CL = 51pF
RL = 3k, CL = 2500pF
Output Transition tHL High-to-Low (Note 5)
Output Transition tLH Low-to-High
q
5
20
±7
17
q
10
100
120
250
15
30
4
7
0.6
1.3
0.5
1.3
µA
mA
µA
kBaud
kBaud
V/µs
V/µs
µs
µs
Input Voltage Thresholds
Hysteresis
Input Low Threshold (VOUT = High)
Input High Threshold (VOUT = Low)
0.8
1.3
V
1.7
2.4
V
q 0.1
0.4
1
V
Input Resistance
Output Leakage Current
Output Voltage
Output Short-Circuit Current
Propagation Delay
VIN = ±10V
SHUTDOWN (Note 4) 0 VOUT VCC
Output Low, IOUT = – 1.6mA
Output High, IOUT = 160µA (VCC = 5V)
Sinking Current, VOUT = VCC
Sourcing Current, VOUT = 0V
Output Transition tHL High-to-Low (Note 6)
Output Transition tLH Low-to-High
3
5
7
k
q
1
10
µA
q
0.2
0.4
V
q 3.5
4.2
V
– 20
– 10
mA
10
20
mA
250 600
ns
350 600
ns
The q denotes specifications which apply over the operating temperature
range.
Note 1: Absolute Maximum Ratings are those values beyond which the life
of the device may be impaired.
Note 2: Testing done at VCC = 5V and VON/OFF = 3V, unless otherwise
specified.
Note 3: Supply current is measured as the average over several charge
pump cycles. C + = C = C1 = C2 = 0.1µF. All outputs are open, with all
driver inputs tied high.
Note 4: Supply current measurements in SHUTDOWN are performed with
VON/OFF 0.1V.
Note 5: For driver delay measurements, RL = 3k and CL = 51pF. Trigger
points are set between the driver’s input logic threshold and the output
transition to the zero crossing (tHL = 1.4V to 0V and tLH = 1.4V to 0V).
Note 6: For receiver delay measurements, CL = 51pF. Trigger points are
set between the receiver’s input logic threshold and the output transition
to standard TTL/CMOS logic threshold (tHL = 1.3V to 2.4V and tLH = 1.7V
to 0.8V).