DS1775
Digital Thermometer and Thermostat in SOT23
the device. Following a clear, a subsequent fault can only
occur if consecutive conversions fall below THYST. This
interrupt/clear process is thus cyclical (TOS, clear, THYST,
clear, TOS, clear, THYST, clear, etc.). Only the first of
multiple consecutive TOS violations activates O.S., even
if each fault is separated by a clearing function. The same
situation applies to multiple consecutive THYST events.
Regardless of the mode chosen, the O.S. output is
open-drain and the active state is set in the configura-
tion register. The power-up default is active low. See the
Programming section for instructions in adjusting the ther-
mostat setpoints, thermostat mode, and O.S. active state.
Programming
There are three areas of interest in programming the
DS1775: the configuration register, the TOS register, and
the THYST register. All programming is done via the 2-wire
interface by setting the pointer to the appropriate location.
Table 2 illustrates the pointer settings for the four registers
of the DS1775.
TOS
MEASURED
TEMPERATURE
THYST
INACTIVE
O.S.
OUTPUT
ACTIVE
CONVERSIONS
COMPARATOR MODE
INACTIVE
O.S.
OUTPUT
ACTIVE
CONVERSIONS
INTERRUPT MODE
ASSUMES A READ
HAS OCCURRED
THIS TRANSFER FUNCTION ASSUMES THE DS1775 IS CONFIGURED SUCH THAT 2
CONSECUTIVE CONVERSIONS OUT OF TOLERANCE CONSTITUTE AND O.S. FAULT
Figure 2. O.S. Output Transfer Function
Table 2. Pointer Register Structure
POINTER
00h
01h
02h
03h
ACTIVE REGISTER
Temperature (default)
Configuration
THYST
TOS
www.maximintegrated.com
Maxim Integrated 7