DS1775
Digital Thermometer and Thermostat in SOT23
Thermostat Setpoints Programming
The thermostat registers (TOS and THYST) can be
programmed or read via the 2-wire interface. TOS is
accessed by setting the DS1775 data pointer to the 03h
location, and to the 02h location for THYST.
The format of the TOS and THYST registers is identical to
that of the Thermometer register; that is, 12-bit 2’s com-
plement representation of the temperature in °C. The user
can program the number of bits (9, 10, 11, or 12) for each
TOS and THYST that corresponds to the thermometer
resolution mode chosen. For example, if the 9-bit mode is
chosen the three least significant bits of TOS and THYST
are ignored by the thermostat comparator. Table 6 shows
the format for both TOS and THYST. The power-up default
for TOS is +80°C and for THYST is +75°C.
If the user does not wish to take advantage of the ther-
mostat capabilities of the DS1775, the 24 bits can be
used for general storage of system data that need not be
maintained following a power loss.
2-WIRE Serial Data Bus
The DS1775 supports a bidirectional 2-wire bus and data
transmission protocol. A device that sends data onto the
bus is defined as a transmitter, and a device receiving
data as a receiver. The device that controls the message
is called a “master”. The devices that are controlled by
the master are “slaves”. The bus must be controlled by
a master device which generates the serial clock (SCL),
controls the bus access, and generates the START and
STOP conditions. The DS1775 operates as a slave on
the 2-wire bus. Connections to the bus are made via the
open-drain I/O lines SDA and SCL.
The following bus protocol has been defined
(see Figure 3):
● Data transfer may be initiated only when the bus is
not busy.
● During data transfer, the data line must remain stable
whenever the clock line is HIGH. Changes in the data
line while the clock line is high are interpreted as con-
trol signals.
Table 6. Thermostat Setpoint (TOS/THYST) Format
S
26
25
24
23
22
21
20
MSb
(UNIT = °C)
LSb
2-1
2-2
2-3
2-4
0
0
0
0
MSB
LSB
TEMPERATURE
(°C)
+80
+75
+10.125
+0.5
0
-0.5
-10.125
-25.0625
-55
DIGITAL OUTPUT
(BINARY)
0101 0000 0000 0000
0100 1011 0000 0000
0000 1010 0010 0000
0000 0000 1000 0000
0000 0000 0000 0000
1111 1111 1000 0000
1111 0101 1110 0000
1110 0110 1111 0000
1100 1001 0000 0000
DIGITAL OUTPUT
(HEX)
5000h
4B00h
0A20h
0080h
0000h
FF80h
F5E0h
E6F0h
C900h
www.maximintegrated.com
Maxim Integrated 9