C-Series Circuit Breaker - Rocker UL Recognized – Ordering Scheme | 9
C
1
Series
C
2
Actuator
3
3
Poles
B
4
Circuit
1 SERIES
C
2 ACTUATOR 1
Two Color Visi-Rocker
C Indicate ON, vertical legend
D Indicate ON, horizontal legend
E Indicate ON, no legend
F Indicate OFF, vertical legend
G Indicate OFF, horizontal legend
H Indicate OFF, no legend
Push-To-Reset, Visi-Rocker
N Indicate OFF, vertical legend
O Indicate OFF, horizontal legend
P Indicate OFF, no legend
Single color
J Vertical legend
K Horizontal legend
L No legend
Push-To-Reset, Single color
R Vertical legend
U Horizontal legend
V No legend
0
5
Aux/Alarm
Switch
14
6
Frequency
& Delay
3 POLES 2
1 One
2 Two
3 Three
4
A
C3 IRCSwUiItTch
Only
(No
Coil)
B Series Trip (Current)
F
G
H
4
4
4,5
Relay Trip (Current)
Relay Trip (Voltage)
Dual Coil with Shunt Trip
C
D
E
4
4
Series Trip (Voltage)
Shunt Trip (Current)
K
4,5
Voltage Coil
Dual Coil with Relay Trip
Shunt Trip (Voltage)
Voltage Coil
5 AUXILIARY / ALARM SWITCH 6
0 without Aux Switch
2 S.P.D.T., 0.110 Q.C. Term.
3 S.P.D.T., 0.139 Solder Lug
4 S.P.D.T., 0.110 Q.C. Term.
(Gold Contacts)
6 S.P.S.T., 0.139 Solder Lug
8 S.P.S.T., 0.187 Q.C. Term.
9 S.P.D.T., 0.187 Q.C. Term.
6 FREQUENCY & DELAY
03
10
7
DC 50/60Hz, Switch Only
DC Instantaneous
11 DC Ultra Short
12 DC Short
14 DC Medium
16
20
7
DC Long
50/60Hz Instantaneous
21 50/60Hz Ultra Short
22 50/60Hz Short
24 50/60Hz Medium
26 50/60Hz Long
30 DC 50/60Hz Instantaneous
31 DC 50/60Hz Ultra Short
32 DC 50/60Hz Short
34 DC 50/60Hz Medium
36
42
44
46
52
54
56
8
8
8
8
8
8
DC 50/60Hz Long
50/60Hz Short, Hi-Inrush
50/60Hz Medium, Hi-Inrush
50/60Hz Long, Hi-Inrush
DC Short, Hi-Inrush
DC Medium, Hi-Inrush
DC Long, Hi-Inrush
Notes:
1 Push-To-Reset actuators have OFF portion of rocker shrouded.
2 Multi-pole breakers have all poles identical except when specifying Auxiliary switch
and/or mixed poles, and have one rocker per breaker. Rocker location as viewed from
front panel: 2 pole – left pole; 3 pole – center pole.
3 Switch Only circuits, rated up to 50 amps and 3 poles, and only available with VDE
Certification when tied to a protected pole (Circuit Code B, C, D or H.), For .02 to
30 amps, select Current Code 630. For 35 - 50 amps, select Current Code 650.
For 55-70 amps, select Current Code 670. For 75-100 amps, select Current Code 810.
4 Circuit Codes D,E,F,G,H & K available with Terminal Codes 1,2,4 & 5 only. Circuit
Codes D,F,H & K available up to 50 amps maximum Current Rating.
5 Consult factory for available Dual Coil options, as special catalog number is
required. Dual Coil Voltage Coils with Shunt Trip Construction trip instantaneously
on line voltage. Dual Coil Voltage Coils require 30VA minimum power to trip
instantaneously and are rated for intermittent duty only.
6 Auxiliary Switch available with Series Trip and Switch Only circuits. On multi-pole
breakers, one auxiliary switch is supplied, mounted in the extreme right pole. Auxiliary
switch codes 2, 3 & 4 are VDE approved.
7 Voltage coils not rated for continuous duty. Available only with delay codes 10 & 20.
8 Available with Circuit Codes B & D only, and up to 50 amps maximum.
9 Current Ratings 60-70 are available up to four poles maximum. Ratings 71-100 are
available up to two poles maximum.
10 Terminal Code 1 available to 60 amps maximum.
11 Terminal Codes 2,4,5 & C available to 50 amps maximum.
12 Terminal Codes 3,6 & 9 available to 100 amps maximum.
13 Terminal Code 7 available to 25 amps maximum.
14 Terminal Code A available to 100 amps maximum.
15 Terminal Codes 7, 9 & C are not VDE approved.
16 Color shown is visi and legend with remainder of rocker black
17 Legend on Push-to-reset bezel/shroud is white when single color rocker is ordered.
Dual = ON-OFF/I-O legend with actuator codes C - G, and J, K, N, O, R, & U. None
= no legend with actuator codes H, L, P, V. Rockerguard available with actuator
codes C - L. Push-to-reset available with actuator codes N, O, P, R, U, V.
18 VDE/TUV approval requires Dual (I-O, ON-OFF) or I-O markings on rocker.
19 VDE/TUV: 30 amps max.; UL/CSA: 50 amps max.; Available in 2 - 4 poles only
and limited to AC Delays. “General Purpose amps” not rated for “full load amps” or
to be used in applications with a motor.
450
7
Current Rating
1
8
Terminal
2
9
Actuator
Color
1
10
Mounting/
Barriers
7 CURRENT RATING (AMPERES)
CODE AMPERES
020 0.020
235 0.350
430 3.000
025 0.025
240 0.400
435 3.500
030 0.030
245 0.450
440 4.000
035 0.035
250 0.500
445 4.500
040 0.040
255 0.550
450 5.000
045 0.045
260 0.600
455 5.500
050 0.050
265 0.650
460 6.000
055 0.055
270 0.700
465 6.500
060 0.060
275 0.750
470 7.000
065 0.065
280 0.800
475 7.500
070 0.070
285 0.850
480 8.000
075 0.075
290 0.900
485 8.500
080 0.080
295 0.950
490 9.000
085 0.085
410 1.000
495 9.500
090 0.090
512 1.250
610 10.000
095 0.095
415 1.500
710 10.500
210 0.100
517 1.750
611 11.000
215 0.150
420 2.000
711 11.500
220 0.200
522 2.250
612 12.000
225 0.250
425 2.500
712 12.500
230
OR
0.300
VOLTAGE
527 2.750
COIL (NORMAL
613 13.000
RATED VOLTAGE)
7
CODE AMPERES
A06 6 DC
A32 32 DC
J12 12 AC
A12 12 DC
A48 48 DC
J18 18 AC
A18 18 DC
A65 65 DC
J24 24 AC
A24 24 DC
J06 6 AC
J48 48 AC
D
11
Agency
Approval
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
630 30.000
635 35.000
640 40.000
650
660
670
680
685
690
695
810
9
9
9
9
9
9
9
50.000
60.000
70.000
80.000
85.000
90.000
95.000
100.00
J65 65 AC
K20 120 AC
L40 240 AC
8
1
2
3
4
5
11111T11102ERSSSSSMctcttIuuurrNeedddAwwM11L0/1M54-0-35x2-230x02.08.8
6
7
12
13
Stud M6
0.250 Double Quick Connect
9
A
14
7/16” Clip Terminal
Plug-In Stud
C 5/16” Clip Terminal
9 ACTUATOR COLOR & LEGEND 16,17,18
Actuator or
Visi-Color Marking:
Marking Color:
Single Color
Color:
I-O ON-OFF Dual/None Rocker/Handle Visi-Rocker
White
AB
1
Black
White
Black
CD
2
White
n/a
Red
FG
3
White
Red
Green
HJ
4
White
Green
Blue
KL
5
White
Blue
Yellow
MN
6
Black
Yellow
Gray
PQ
7
Black
Gray
Orange
RS
8
Black
Orange
10 MOUNTING / BARRIERS 1
STANDARD ROCKER BEZEL
1 6-32 x 0.195 inches
2
3
19
6-32 x 0.195 inches
6-32 x 0.195 inches
4 ISO M3 x 5mm
5
6
19
ISO M3 x 5mm
ISO M3 x 5mm
ROCKERGUARD BEZEL
A 6-32 x 0.195 inches
C
E
19
6-32 x 0.195 inches
6-32 x 0.195 inches
G ISO M3 x 5mm
J
L
19
ISO M3 x 5mm
ISO M3 x 5mm
PUSH-TO-RESET BEZEL
B 6-32 x 0.195 inches
D
F
19
6-32 x 0.195 inches
6-32 x 0.195 inches
H ISO M3 x 5mm
J
M
19
ISO M3 x 5mm
ISO M3 x 5mm
BARRIERS
no
yes
yes
no
yes
yes
no
yes
yes
no
yes
yes
no
yes
yes
no
yes
yes
VOLTAGE
<300
<300
≥300
<300
<300
≥300
<300
<300
≥300
<300
<300
≥300
<300
<300
≥300
<300
<300
≥300
11 AGENCY APPROVAL
C UL Recognized & CSA Accepted
D VDE Certified, UL Recognized & CSA Accepted
E TUV Certified, UL Recognized & CSA Accepted
H UL489 Construction: VDE Certified, UL Recognized & CSA Accepted
I UL Recognized STD 1077, UL Recognized 1500 (ignition protected),
& CSA Accepted
L UL489 Construction: UL Recognized & CSA Accepted
R UL489 Construction: TUV Certified, UL Recognized & CSA Accepted