DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

HCPL-3150-060E 查看數據表(PDF) - Avago Technologies

零件编号
产品描述 (功能)
生产厂家
HCPL-3150-060E
Avagotech
Avago Technologies Avagotech
HCPL-3150-060E Datasheet PDF : 21 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Recommended Pb-Free IR Profile
Recommended reflow condition as per JEDEC Standard, J-STD-020 (latest revision). Non-Halide Flux should be used.
Regulatory Information
The HCPL-3150 and HCPL-315J have been approved by the following organizations:
UL
Recognized under UL 1577, Component Recognition
Program, File E55361.
CSA
Approved under CSA Component Acceptance Notice
#5, File CA 88324.
IEC/EN/DIN EN 60747-5-2
Approved under:
IEC 60747-5-5:1997 + A1:2002
EN 60747-5-2:2001 + A1:2002
DIN EN 60747-5-2 (VDE 0884
Teil 2):2003-01.
(Option 060 and HCPL-315J only)
IEC/EN/DIN EN 60747-5-2 Insulation Characteristics
Description
Symbol
Installation classification per DIN VDE
0110/1.89, Table 1
for rated mains voltage ≤ 150 Vrms
for rated mains voltage ≤ 300 Vrms
for rated mains voltage ≤ 600 Vrms
for rated mains voltage ≤ 1000Vrms
Climatic Classification
55/100/21
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
V
IORM
Input to Output Test Voltage, Method b*
V x 1.875 = V , 100% Production
IORM
PR
Test with tm = 1 sec,
VPR
Partial discharge < 5 pC
Input to Output Test Voltage, Method a*
V x 1.6 = V , Type and Sample
IORM
PR
Test, t = 10 sec,
V
m
PR
Partial discharge < 5 pC
Highest Allowable Overvoltage*
(Transient Overvoltage t = 60 sec)
ini
Safety-Limiting Values – Maximum Values
Allowed in the Event of a Failure, Also
See Figure 37, Thermal Derating Curve.
Case TemperatureT
S
Input Current
Output Power
Insulation Resistance at T , V = 500 V
S IO
VIOTM
175
I
S, INPUT
P
S, OUTPUT
R
S
HCPL-3150#060
I - IV
I - III
I - II
55/100/21
2
630
1181
945
6000
175
230
600
≥ 109
HCPL-315J
I - IV
I - IV
I - IV
I-III
2
1230
2306
1968
8000
°C
400
1200
≥ 109
Unit
Vpeak
Vpeak
Vpeak
Vpeak
mA
mW
Ω
*Refer to the front of the optocoupler section of the current Catalog, under Product Safety Regulations section IEC/EN/DIN EN 60747-5-2, for a
detailed description of Method a and Method b partial discharge test profiles.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in application.
5

Share Link: 