NCS37012
Table 3. ABSOLUTE MAXIMUM RATINGS
Rating
Symbol
Value
Unit
Supply Voltage Range
Vs
6.0 to 12 V
V
Input Voltage Range (Note 1)
Output Voltage Range
Vin
0.3 to 6.0
V
Vout
0.3 to 6.0 V or (Vin + 0.3),
V
whichever is lower
Maximum Junction Temperature
TJ(max)
140
°C
Storage Temperature Range
TSTG
65 to 150
°C
ESD Capability, Human Body Model (Note 2)
ESDHBM
2
kV
ESD Capability, Machine Model (Note 2)
ESDMM
200
V
Lead Temperature Soldering
TSLD
260
°C
Reflow (SMD Styles Only), PbFree Versions (Note 3)
Stresses exceeding Maximum Ratings may damage the device. Maximum Ratings are stress ratings only. Functional operation above the
Recommended Operating Conditions is not implied. Extended exposure to stresses above the Recommended Operating Conditions may affect
device reliability.
1. Refer to ELECTRICAL CHARACTERISTICS and APPLICATION INFORMATION for Safe Operating Area.
2. This device series incorporates ESD protection and is tested by the following methods:
ESD Human Body Model tested per AECQ100002 (EIA/JESD22A114)
ESD Machine Model tested per AECQ100003 (EIA/JESD22A115)
Latchup Current Maximum Rating: v150 mA per JEDEC standard: JESD78
3. For information, please refer to our Soldering and Mounting Techniques Reference Manual, SOLDERRM/D
Table 4. THERMAL CHARACTERISTICS
Rating
Symbol
Value
Thermal Characteristics, QFN16, 3x3.3 mm (Note 4)
Thermal Resistance, JunctiontoAir (Note 5)
Thermal Reference, JunctiontoLead2 (Note 5)
Thermal Characteristics, TSOP5 (Note 4)
Thermal Resistance, JunctiontoAir (Note 5)
RqJA
RYJL
RqJA
TBD
TBD
TBD
4. Refer to ELECTRICAL CHARACTERISTICS and APPLICATION INFORMATION for Safe Operating Area.
5. Values based on copper area of 645 mm2 (or 1 in2) of 1 oz copper thickness and FR4 PCB substrate.
Unit
°C/W
°C/W
Table 5. OPERATING RANGES (Note 6)
Parameter
Conditions
Min
Typ
Operating Temperature
40
IDD in typical power state
2.0
Stimulus Generator Frequency
Tritone
3.1
SCR Trigger Current
SCR Trigger output voltage
With 5 V supply
4.5
Fault Current Sensitivity
Programmable with CTresD
4.6
4.8
Ground Fault Response Time
5 20 mA
150
Ground Fault Response Time
20 40 mA
75
Ground Fault Response Time
>40 mA
25
Saturation Fault Response Time
>300 mA
1.4
CT Turns Ratio
200
Ground – Neutral Detection Threshold
Total series impedance (Rn and Rg)
3.0
Internal Oscillator Frequency
2.0
CT Stimulus Current
Internally limited
CT Driver Closed Loop BW
6. Refer to ELECTRICAL CHARACTERISTICS and APPLICATION INFORMATION for Safe Operating Area.
Max Units
85
C
mA
3.4
kHz
8.0
mA
5.5
V
5.0
mA
ms
ms
ms
ms
300
6.0
W
MHz
1.0
mA
500
kHz
http://onsemi.com
4