µPD16431A
(2) Status command
This command sets a data write/read mode, turns on/off display, and sets a latch address.
MSB
LSB
1 × × b4 b3 b2 b1 b0
× : Don’t Care
Sets data write/read mode.
0: Writes display data to output latch
1: Reads key data
Turns on/off display
00: Forcibly turns off display (all segments and LEDs off).
Stops key scanning.
01: Prohibited
10: Normal operation
11: Don’t care
Sets latch address.
00: COM1
01: COM2
10: COM3
11: COM4
Values when power is applied
××00000