INPUT SPECIFICATIONS:
Voltage …....………........…........................................... 90~264Vac
Frequency ………………………………………….……………..... 47 to 63Hz
Inrush Current ………………….……………................... 0.7A max.
Inrush Current ………………….……………................... 50A max. @240Vac
Conducted EMI …………………………….…………... CISPR/FCC Class B
Leakage Current …………………………………………………. 0.25mA max.
OUTPUT SPECIFICATIONS:
Holdup Time ……………………………………………… 10ms typ. @115Vac
Short Circuit Protection …………….…………… Continuous(Auto Recovery)
Over Voltage Protection ………………. ............... TVS Component to Clamp
Temperature Coefficient ……………………............................… ±0.05%/
GENERAL SPECIFICATIONS:
Isolation ………………………………….…..…… Input to output = 4,242VDC
Operating Temperature ................................... 0 ~ 60(see derating curve)
Storage Temperature ………………….…………...….......……........ -20~85
Humidity …………………...….......…........... 93% RH max. Non condensing
Cooling ………………………………….………………….. Natural Convection
Switching Frequency ………………………….……………….. 65KHz Typical
MTBF …….… MIL-HDBK-217F, GB, 25/115VAC ……… 300K hrs min.
Altitude …………………………………………………………………… 2000m
Dimensions ……….….. 3.169x1.932x2.205Inches (80.5x49.06x56.00mm)
Weight ………………………………………………….…… 280g(0.62 Pounds)
SAFETY AND EMC:
Emission and lmmunity ……….… EN55022 Class B, FCC Part 15 Class B
EN61000-6-3, EN61000-3-2, EN61000-3-3
EN55024, EN61204-3, EN61000-6-1
Safety …………………………….…… IEC60950-1, EN60950-1, UL60950-1
NOTE:
1. Add a 0.1uF ceramic capacitor and a 10uF E.L. capacitor to output for
Ripple & Noise measuring @20MHz BW.
2. Voltage setpoint at 60% full load.
3. Line regulation measured from 100Vac to 240Vac, full load.
4. Load regulation measured from 60% to 100% full load and from 60% to
20% load (60% +/- 40% full load).
5. Typical efficiency at 230VAC and full load at 25.
6. ”Various TR Series adapters are PSE certified. PSE certification
alone is not sufficient for importation into Japan. A valid PSE mark
must contain the name of the importer as shown in the example below.
If PSE mark is required, the name of the registered importer must be
supplied to Cincon on order placement. Product labels will not contain
PSE mark if importer name is not supplied. Consult factory or local
representative for details”.
TRG25 Series Derating Curve
100%
75%
50%
25%
0%
0
20LFM(Natural Conv ection)
10
20
30
40
50
60
Ambient Temperature(oC)
Typical at 25˚C, nominal line and 75% load, unless otherwise Specified