ISL60002
Common Electrical Specifications ISL60002 -10, -11, -12, -18, -20, and -25
Operating Conditions: VIN = 3.0V, IOUT = 0mA, COUT = 0.001µF, TA = -40 to +85°C, unless otherwise specified. Boldface limits apply over the operating
temperature range, -40°C to +85°C
SYMBOL
PARAMETER
CONDITIONS
MIN
MAX
(Note
(Note
10)
TYP
10)
UNITS
TC VOUT
Output Voltage Temperature
Coefficient (Note 11)
20
ppm/°C
IIN
ΔVOUT/ΔVIN
ΔVOUT/ΔIOUT
Supply Current
Line Regulation
Load Regulation
ΔVOUT/ΔTA
ΔVOUT/Δt
ISC
Thermal Hysteresis (Note 12)
Long Term Stability (Note 13)
Short Circuit Current (to GND)
(Note 14)
+2.7V VIN +5.5V
0mA ISOURCE 7mA
-7mA ISINK 0mA
ΔTA = +125°C
TA = +25°C; First 1khrs
TA = +25°C
350
900
80
250
25
100
50
150
100
50
50
nA
µV/V
µV/mA
µV/mA
ppm
ppm
mA
VN
Output Voltage Noise
0.1Hz f 10Hz
30
µVP-P
NOTES:
10. Compliance to datasheet limits is assured by one or more methods: production test, characterization and/or design.
11. Over the specified temperature range. Temperature coefficient is measured by the box method whereby the change in VOUT is divided by the
temperature range: (-40°C to +85°C = +125°C, or -40°C to +105°C = +145°C for the ISL60002-33).
12. Thermal Hysteresis is the change in VOUT measured @ TA = +25°C after temperature cycling over a specified range, ΔTA, VOUT is read initially at
TA = +25°C for the device under test. The device is temperature cycled and a second VOUT measurement is taken at +25°C. The difference between
the initial VOUT reading and the second VOUT reading is then expressed in ppm. For ΔTA = +125°C, the device under is cycled from +25°C to +85°C
to -40°C to +25°C, and for ΔTA = +145°C, the device under is cycled from +25°C to +105°C to -40°C to +25°C
13. Long term drift is logarithmic in nature and diminishes over time. Drift after the first 1000 hours will be approximately 10ppm.
14. Short Circuit Current (to VCC) for ISL60002-25 at VIN = 5.0V and +25°C is typically around 30mA. Shorting VOUT to VCC is not recommended due to
risk of resetting the part.