Qualification and Reliability
The R485-type receiver is scheduled to complete the following qualification tests to meet the intent of Telcordia
Technologies GR-468-CORE.
Table 4. R485 Qualification Information
Test
Reference
Conditions
Code
Type
Sample
Size
Pass/Fail Criteria
Note
Mechanical Shock MIL-STD-883
Method 2002
Condition B
5 times/axis
500 G, 1 ms
Sine Vibration
MIL-STD-883
Method 2007
Condition A
20 G, 20 Hz—2000 Hz
4 min./cycle
4 cycles/axis
Thermal Shock MIL-STD-883
Method 1011
∆T = 100 °C
Solderability
MIL-STD-883 (Package Supplier Test)
Method 2003
Lead
Integrity
MIL-STD-883 (Package Supplier Test)
Method 2004
Solvent
Resistance
MIL-STD-883 (Package Supplier Test)
Method 2015
R485
R480
R485
R480
R485
R480
—
—
—
11 Change in Receiver Qualified by
Pieces Sensitivity: –1.5 dB T48/P172
11 Change in Receiver Qualified by
Pieces Sensitivity: –1.5 dB T48/P172
11
Pieces
—
—
—
Physical Attributes Qualified by
and Leak Check T48/P172
—
Qualified by
T48
—
Qualified by
T48
—
Qualified by
T48
Fiber Pull
Accelerating
Aging
(HTOB)
GR-468-CORE
Table 6
MIL-STD-883
Method 1005
1 kg; 3 times; 5 s
85 °C under bias,
2000 hours
R485
R480
R485
R480
High Temperature GR-468-CORE
Storage
Table 6
85 °C storage,
2000 hours
Temperature GR-468-CORE –40 °C to +85 °C
Cycling
Section 5.20 100 Cycles for Pass/Fail
Temperature GR-468-CORE
Humidity Bias
Table 6
85 °C/85% RH
1000 hours
Internal Water MIL-STD-883 5000 ppm Water Vapor
Vapor
Method 1018
ESD
GR-468-CORE Human-Body Model
Section 5.22
R485
R480
R485
R480
R485
R480
R485
R480
R485
R480
11 Change in Receiver Qualified by
Pieces Sensitivity: –1.5 dB P172
25 Change in Receiver Qualified by
Pieces Sensitivity: –1.5 dB T48/P172;
Refer to
Chip Data
11 Change in Receiver Qualified by
Pieces Sensitivity: –1.5 dB T48/P172
11 Change in Receiver Qualified by
Pieces Sensitivity: –1.5 dB T48/P172
11 Change in Receiver Qualified by
Pieces Sensitivity: –1.5 dB T48/P172
11 Change in Receiver Qualified by
Pieces Sensitivity: –1.5 dB T48/P172
6
Threshold
—
Pieces Minimum: 500 V
6
Agere Systems Inc.